<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>11</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>09</Month>
					<Day>12</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical Study on the Effect of Blower Location on the Maximum Temperature and Spread of Smoke In Case Of Fire inside Tunnels</ArticleTitle>
<VernacularTitle>Numerical Study on the Effect of Blower Location on the Maximum Temperature and Spread of Smoke In Case Of Fire inside Tunnels</VernacularTitle>
			<FirstPage>3241</FirstPage>
			<LastPage>3256</LastPage>
			<ELocationID EIdType="pii">3571</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16048.6261</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Seyyed Omid</FirstName>
					<LastName>Haghani</LastName>
<Affiliation>Department of Mechanical Engineering, khayyam university, mashhad, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ebrahim</FirstName>
					<LastName>Barati</LastName>
<Affiliation>Mechanical engineering, Khayyam university</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>03</Month>
					<Day>26</Day>
				</PubDate>
			</History>
		<Abstract>Designing an efficient emergency ventilation system is one of the main approaches to prevent the perilous fire in tunnel phenomenon. One of the most considerable factors in smoke control is critical velocity. In the present work, a parameter is called a critical volume flux, which indicates    at least a volumetric flow that prevents smoke from flowing upstream of the fire. In this study, fire in tunnel is simulated using fire dynamics simulator code and the effect of blower location on maximum temperature, spread of smoke and critical volume flux of fire in the tunnel have been investigated. The results show that the blower location has a significant effect on critical velocity and volumetric flux and it can reduce critical volumetric flux by at least 11 percent. Also, considering different conditions in the blower system, the effect of fire source height has been investigated. The results also show that increasing the fire source’s height does not have a significant effect on volumetric flux and critical velocity. The results show that the approach of the blower to the fire would reduce the smoke back- layering length and increase the maximum temperature.</Abstract>
			<OtherAbstract Language="FA">Designing an efficient emergency ventilation system is one of the main approaches to prevent the perilous fire in tunnel phenomenon. One of the most considerable factors in smoke control is critical velocity. In the present work, a parameter is called a critical volume flux, which indicates    at least a volumetric flow that prevents smoke from flowing upstream of the fire. In this study, fire in tunnel is simulated using fire dynamics simulator code and the effect of blower location on maximum temperature, spread of smoke and critical volume flux of fire in the tunnel have been investigated. The results show that the blower location has a significant effect on critical velocity and volumetric flux and it can reduce critical volumetric flux by at least 11 percent. Also, considering different conditions in the blower system, the effect of fire source height has been investigated. The results also show that increasing the fire source’s height does not have a significant effect on volumetric flux and critical velocity. The results show that the approach of the blower to the fire would reduce the smoke back- layering length and increase the maximum temperature.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">blower location</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fire</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">critical volume flux</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">maximum temperature</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3571_f8f5161cf94df05793592f5fab95138b.pdf</ArchiveCopySource>
</Article>