<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>54</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2022</Year>
					<Month>05</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Simulation of a Forced Multiple Effect Brine Concentration Process</ArticleTitle>
<VernacularTitle>Simulation of a Forced Multiple Effect Brine Concentration Process</VernacularTitle>
			<FirstPage>509</FirstPage>
			<LastPage>530</LastPage>
			<ELocationID EIdType="pii">4529</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2021.20091.7165</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Abbas</FirstName>
					<LastName>Forouzi Feshalami</LastName>
<Affiliation>MSc. Student of Mechanical  Engineering at  Guilan University</Affiliation>
<Identifier Source="ORCID">0000-0001-8465-6901</Identifier>

</Author>
<Author>
					<FirstName>Ramin</FirstName>
					<LastName>Kouhikamali</LastName>
<Affiliation>Faculty of Mechanical Engineering, University of Guilan</Affiliation>
<Identifier Source="ORCID">0000-0002-8004-0242</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2021</Year>
					<Month>05</Month>
					<Day>26</Day>
				</PubDate>
			</History>
		<Abstract>Brine Concentration is a comprehensive process and has an effective role in reducing environmental pollution due to desalination plant wastewater. In this study, the equations, for feed-forward forced convective falling film brine concentrators, with the desired number of effects and thermal vapor compression have been solved by MATLAB code. Thermodynamic modeling results of a two stage brine concentrator represented that 6.25 ton/hr feed with 90000 ppm concentration produces 5 ton/hr fresh water and 1.25 ton/hr wastewater with 450000 ppm concentration. The gained output ratio of plant is 2.63 and the specific heat transfer area is 74.3 m&lt;sup&gt;2&lt;/sup&gt;s/kg. Also, by thermohydraulic modeling, to control the sediment rate with the limitations of allowable pressure drop and stream velocity in different tube lengths and diameters and evaporator number of passes, heat transfer area and the number of tubes have been calculated. Finally, the effects of design variables on gained output ratio and specific heat transfer area are investigated. The results represented that effects number, feed, and driving steam temperature are the three most important variables since increasing the effects number causes a 17% increase in gained output ratio and 23.5% increase in the specific heat transfer area. Increasing 1 ֯C in feed and motive vapor temperature lead to a 2.5% increase and 3% decrease in the specific heat transfer area. But these two don’t have any effect on gained output ratio.</Abstract>
			<OtherAbstract Language="FA">Brine Concentration is a comprehensive process and has an effective role in reducing environmental pollution due to desalination plant wastewater. In this study, the equations, for feed-forward forced convective falling film brine concentrators, with the desired number of effects and thermal vapor compression have been solved by MATLAB code. Thermodynamic modeling results of a two stage brine concentrator represented that 6.25 ton/hr feed with 90000 ppm concentration produces 5 ton/hr fresh water and 1.25 ton/hr wastewater with 450000 ppm concentration. The gained output ratio of plant is 2.63 and the specific heat transfer area is 74.3 m&lt;sup&gt;2&lt;/sup&gt;s/kg. Also, by thermohydraulic modeling, to control the sediment rate with the limitations of allowable pressure drop and stream velocity in different tube lengths and diameters and evaporator number of passes, heat transfer area and the number of tubes have been calculated. Finally, the effects of design variables on gained output ratio and specific heat transfer area are investigated. The results represented that effects number, feed, and driving steam temperature are the three most important variables since increasing the effects number causes a 17% increase in gained output ratio and 23.5% increase in the specific heat transfer area. Increasing 1 ֯C in feed and motive vapor temperature lead to a 2.5% increase and 3% decrease in the specific heat transfer area. But these two don’t have any effect on gained output ratio.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Brine Concentrator unit</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Falling film evaporator</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermodynamic and thermohydraulic design</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Forced convective flow</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_4529_9713faa264b94e2bf346a1bb52587fd8.pdf</ArchiveCopySource>
</Article>
</ArticleSet>