<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>45</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2013</Year>
					<Month>08</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>The Optimization of Heat Transfer Distribution in a Heated Room Using Convective Thermal Panels for Achievement of Thermal Comfort</ArticleTitle>
<VernacularTitle>The Optimization of Heat Transfer Distribution in a Heated Room Using Convective Thermal Panels for Achievement of Thermal Comfort</VernacularTitle>
			<FirstPage>63</FirstPage>
			<LastPage>73</LastPage>
			<ELocationID EIdType="pii">6</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2013.6</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Ali</FirstName>
					<LastName>Hoseini Moghadam Emami</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>Ali</FirstName>
					<LastName>Keshavarz Valian</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>Nabi</FirstName>
					<LastName>Jahan Tigh</LastName>
<Affiliation></Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2014</Year>
					<Month>03</Month>
					<Day>12</Day>
				</PubDate>
			</History>
		    <Abstract>In the present study, the heat transfer, moisture distribution, air flow and thermal comfort in a residual roomwhich is warmed by convectional thermal panels under different environmental conditions was assessednumerically. The analyzed model is the real and dynamic 3D simulation, and a virtual thermal manikin with realphysiological dimensions has been added to the model. The manikin is standing at the center of room. The roomhas dimensions of 3*4*4 m with an inlet device that has dimensions of 1.28*0.0542 m and two outlet deviceswith dimensions of 0.054*1.022 m . The inlet and outlet devices have been modeled above and under the door.To determine the optimal arrangement and number of panels, three models have been studied. The modelsinclude one panel with real dimensions of 1.242*0.812 m , two panels with real dimensions 0.61*0.962 m andthree panels with real dimensions 0.61*0.81 2 m , with a thickness of 20cm in all panels. The uniformdistribution of temperature, velocity and moisture, and proper and symmetric arrangement of panels, inlets andoutlets decrease the energy consumption and satisfy the thermal comfort of inhabitants. Thermal loss increasesdue to the panels under the window. It was concluded that using two panels with smaller dimensions at the leftand right of the model instead of one panel under the window or three panels at the left, right and under thewindow significantly reduces the thermal loss.</Abstract>
			<OtherAbstract Language="FA">In the present study, the heat transfer, moisture distribution, air flow and thermal comfort in a residual roomwhich is warmed by convectional thermal panels under different environmental conditions was assessednumerically. The analyzed model is the real and dynamic 3D simulation, and a virtual thermal manikin with realphysiological dimensions has been added to the model. The manikin is standing at the center of room. The roomhas dimensions of 3*4*4 m with an inlet device that has dimensions of 1.28*0.0542 m and two outlet deviceswith dimensions of 0.054*1.022 m . The inlet and outlet devices have been modeled above and under the door.To determine the optimal arrangement and number of panels, three models have been studied. The modelsinclude one panel with real dimensions of 1.242*0.812 m , two panels with real dimensions 0.61*0.962 m andthree panels with real dimensions 0.61*0.81 2 m , with a thickness of 20cm in all panels. The uniformdistribution of temperature, velocity and moisture, and proper and symmetric arrangement of panels, inlets andoutlets decrease the energy consumption and satisfy the thermal comfort of inhabitants. Thermal loss increasesdue to the panels under the window. It was concluded that using two panels with smaller dimensions at the leftand right of the model instead of one panel under the window or three panels at the left, right and under thewindow significantly reduces the thermal loss.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Virtual Manikin</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal comfort</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Convectional Panels</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Optimal Conditions</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Energy Consumption Decrease</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_6_1679091c5a880faf6fb5e6087eb1b2dc.pdf</ArchiveCopySource>
</Article>
</ArticleSet>