<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>07</Month>
					<Day>03</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical Study of the Flat Flame Burner Power Effect on the Producing Uniform
Temperature Distribution in Cracking Furnaces</ArticleTitle>
<VernacularTitle>Numerical Study of the Flat Flame Burner Power Effect on the Producing Uniform
Temperature Distribution in Cracking Furnaces</VernacularTitle>
			<FirstPage>1379</FirstPage>
			<LastPage>1396</LastPage>
			<ELocationID EIdType="pii">2970</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14064.5791</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mehran</FirstName>
					<LastName>Mirbagheri</LastName>
<Affiliation>Energy Conversion , Mechanical Engineering , Tarbiat Modares University , Tehran , Iran</Affiliation>

</Author>
<Author>
					<FirstName>Kiumars</FirstName>
					<LastName>Mazaheri</LastName>
<Affiliation>Faculty of Mechanical Engineering, Tarbiat Modares University</Affiliation>

</Author>
<Author>
					<FirstName>Esmaeil</FirstName>
					<LastName>Ebrahimi</LastName>
<Affiliation>Faculty of Mechanical Engineering , Tarbiat Modares University</Affiliation>

</Author>
<Author>
					<FirstName>Alireza</FirstName>
					<LastName>Alipoor</LastName>
<Affiliation>Faculty of Mechanical Engineering , Shahid Chamran University</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>02</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		    <Abstract>In the present study, with the help of numerical study, the study of the uniform heat fluxformation on process tubes as the main parameter in cracking furnaces has been investigated using flatflame burners with different thermal powers. Due to the lack of experimental data for solver validation,two problems of swirl burner and channel with conjugate heat transfer of combustion gases and solidsurface have been used. To carry out simulations, the chtMultiRegionReactingFoam solver in OpenFOAMsoftware has been developed by adding the conjugate heat transfer capability to the reactingFoam solver.In simulations, k-ω shear stress transport turbulence model has been used for turbulence modeling. Theresults of the simulations show that the use of a flat flame burner in cracking furnaces allows for theuniform temperature distribution in the furnace with the low maximum combustion temperature. Also, tocreate the appropriate heat flux around the pipes so that the proper temperature distribution for crackingreactions is provided, the minimum heat flux of the flat flame burners is required, which in less than that,the appropriate temperature distribution does not occur on the pipes.</Abstract>
			<OtherAbstract Language="FA">In the present study, with the help of numerical study, the study of the uniform heat fluxformation on process tubes as the main parameter in cracking furnaces has been investigated using flatflame burners with different thermal powers. Due to the lack of experimental data for solver validation,two problems of swirl burner and channel with conjugate heat transfer of combustion gases and solidsurface have been used. To carry out simulations, the chtMultiRegionReactingFoam solver in OpenFOAMsoftware has been developed by adding the conjugate heat transfer capability to the reactingFoam solver.In simulations, k-ω shear stress transport turbulence model has been used for turbulence modeling. Theresults of the simulations show that the use of a flat flame burner in cracking furnaces allows for theuniform temperature distribution in the furnace with the low maximum combustion temperature. Also, tocreate the appropriate heat flux around the pipes so that the proper temperature distribution for crackingreactions is provided, the minimum heat flux of the flat flame burners is required, which in less than that,the appropriate temperature distribution does not occur on the pipes.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Cracking Furnace</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Flat Flame Burner</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Benchmark Problem</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Heat Flux</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Combustion Simulation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_2970_6db291ac9963003618ca6aa15063c4d6.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>28</Day>
				</PubDate>
			</Journal>
<ArticleTitle>An Empirical Study on Dropwise Condensation Occurred on  Surfaces Hydrophobized Using a Single-Step Electrodeposition</ArticleTitle>
<VernacularTitle>An Empirical Study on Dropwise Condensation Occurred on  Surfaces Hydrophobized Using a Single-Step Electrodeposition</VernacularTitle>
			<FirstPage>1397</FirstPage>
			<LastPage>1412</LastPage>
			<ELocationID EIdType="pii">3249</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.14776.5937</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Hamid Reza</FirstName>
					<LastName>Talesh Bahramia</LastName>
<Affiliation>School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Alireza</FirstName>
					<LastName>Azizi</LastName>
<Affiliation>School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Hamid</FirstName>
					<LastName>Saffari</LastName>
<Affiliation>School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, Iran.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>08</Month>
					<Day>02</Day>
				</PubDate>
			</History>
		    <Abstract>Dropwise condensation occurs on hydrophobic and superhydrophobic surfaces. The rate of heat transfer depends mostly on the preparing process of hydrophobic surface. Two main features of hydrophobic surfaces are existing micro-nanostructures and their low surface energy. In this paper, a one-step electrodeposition process is used to produce the necessary micro-nanostructures on copper surfaces and a self-assembled mono-layer of 1-Octaecanethiol as surface energy reducing agent. Effects of different electrochemical cell parameters such as electrical current and time of process on the dropwisecondensation heat transfer are investigated. The heat transfer experiments are performed in a device fabricated for this purpose. The surface of the specimens is analyzed using scanning electron microscopy images and X-ray diffraction analysis. The results show that some microstructures made from copper grow on the surface. The results show that current and process time have positive effects on the dropwise condensation heat transfer. It has been seen that surfaces fabricated at low electrodeposition time (15 and 45 sec) have a worse dropwise heat transfer rate than filmwise condensation heat transfer. On the other hand, higher electrodeposition times (135 sec) give 2-4 times higher heat transfer than filmwise heattransfer in the sub-cooling range lower than 10 Kelvin.</Abstract>
			<OtherAbstract Language="FA">Dropwise condensation occurs on hydrophobic and superhydrophobic surfaces. The rate of heat transfer depends mostly on the preparing process of hydrophobic surface. Two main features of hydrophobic surfaces are existing micro-nanostructures and their low surface energy. In this paper, a one-step electrodeposition process is used to produce the necessary micro-nanostructures on copper surfaces and a self-assembled mono-layer of 1-Octaecanethiol as surface energy reducing agent. Effects of different electrochemical cell parameters such as electrical current and time of process on the dropwisecondensation heat transfer are investigated. The heat transfer experiments are performed in a device fabricated for this purpose. The surface of the specimens is analyzed using scanning electron microscopy images and X-ray diffraction analysis. The results show that some microstructures made from copper grow on the surface. The results show that current and process time have positive effects on the dropwise condensation heat transfer. It has been seen that surfaces fabricated at low electrodeposition time (15 and 45 sec) have a worse dropwise heat transfer rate than filmwise condensation heat transfer. On the other hand, higher electrodeposition times (135 sec) give 2-4 times higher heat transfer than filmwise heattransfer in the sub-cooling range lower than 10 Kelvin.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Dropwise Condensation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Superhydrophobic Surfaces</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Self-assembly</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electrodeposition</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Phase change</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3249_0613239e122094abb4ef998c01d16958.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>16</Day>
				</PubDate>
			</Journal>
<ArticleTitle>The Thermodynamic Analysis of New Combined Cycle Using Sabalan Geothermal
Wells and Liquefied Natural Gas Cold EnergyThe Thermodynamic Analysis of New Combined Cycle Using Sabalan Geothermal Wells and Liquefied Natural Gas Cold Energy</ArticleTitle>
<VernacularTitle>The Thermodynamic Analysis of New Combined Cycle Using Sabalan Geothermal
Wells and Liquefied Natural Gas Cold EnergyThe Thermodynamic Analysis of New Combined Cycle Using Sabalan Geothermal Wells and Liquefied Natural Gas Cold Energy</VernacularTitle>
			<FirstPage>1413</FirstPage>
			<LastPage>1428</LastPage>
			<ELocationID EIdType="pii">3236</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.14977.5987</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mehran</FirstName>
					<LastName>Abdolalipouradl</LastName>
<Affiliation>Mechanical Engineering Department, Faculty of engineering, Urmia University, Urmia, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Shahram</FirstName>
					<LastName>Khalilarya</LastName>
<Affiliation></Affiliation>
<Identifier Source="ORCID">0000-0002-6434-852X</Identifier>

</Author>
<Author>
					<FirstName>Samad</FirstName>
					<LastName>Jafarmadar</LastName>
<Affiliation>Mechanical Engineering Department, Faculty of engineering, Urmia University, Urmia, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>09</Month>
					<Day>14</Day>
				</PubDate>
			</History>
		    <Abstract>A new configuration base on the Sabalan geothermal wells is proposed to utilize two wells with different thermodynamic properties in Sabalan region in Iran and generate more power as well as supply of natural gas from liquefied natural gas. A Kalina cycle and Transcritical CO2 Rankine cycle are using Sabalan geothermal wells as a heat source and liquefied natural gas as a thermal heat sink. A comprehensive parametric study is investigated to understand the characteristics of the system. The results show that the thermal and exergy efficiencies can be increased by increasing separator 1&amp;2 pressures. Also decreasing the higher pressure of the Kalina cycle and pinch point temperature of evaporators lead to increasing the net output power, thermal and exergy efficiencies. Additionally, exergy analysis results showed that the highest exergy destruction rate belongs to the heat exchanger 1&amp;2. Optimization of the proposed cycle is performed by using genetic algorithm method, and it is observed in the optimal condition that the net output power, thermal efficiency, and exergy efficiency can be obtained as 30610 kW, 29.16%, and 56.92%, respectively. The results of this study indicate that the net output power and thermal efficiency is better performance compared to the previous studies.</Abstract>
			<OtherAbstract Language="FA">A new configuration base on the Sabalan geothermal wells is proposed to utilize two wells with different thermodynamic properties in Sabalan region in Iran and generate more power as well as supply of natural gas from liquefied natural gas. A Kalina cycle and Transcritical CO2 Rankine cycle are using Sabalan geothermal wells as a heat source and liquefied natural gas as a thermal heat sink. A comprehensive parametric study is investigated to understand the characteristics of the system. The results show that the thermal and exergy efficiencies can be increased by increasing separator 1&amp;2 pressures. Also decreasing the higher pressure of the Kalina cycle and pinch point temperature of evaporators lead to increasing the net output power, thermal and exergy efficiencies. Additionally, exergy analysis results showed that the highest exergy destruction rate belongs to the heat exchanger 1&amp;2. Optimization of the proposed cycle is performed by using genetic algorithm method, and it is observed in the optimal condition that the net output power, thermal efficiency, and exergy efficiency can be obtained as 30610 kW, 29.16%, and 56.92%, respectively. The results of this study indicate that the net output power and thermal efficiency is better performance compared to the previous studies.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Thermodynamic analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Single flash</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Liquefied Natural Gas</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sabalan geothermal power plant</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3236_ddcb155487b88aaa80aed158006bdbdf.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>09</Month>
					<Day>14</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Simulation of diffusion absorption refrigeration cycle with car exhaust heat source
and improving cycle performance at low engine speeds</ArticleTitle>
<VernacularTitle>Simulation of diffusion absorption refrigeration cycle with car exhaust heat source
and improving cycle performance at low engine speeds</VernacularTitle>
			<FirstPage>1429</FirstPage>
			<LastPage>1442</LastPage>
			<ELocationID EIdType="pii">3075</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14373.5845</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Bazargan</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>Ramin</FirstName>
					<LastName>Farzadi</LastName>
<Affiliation>K.N.Toosi university of technology</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>04</Month>
					<Day>26</Day>
				</PubDate>
			</History>
		    <Abstract>A diffusion absorption refrigeration cycle as a car refrigerator, which uses the car exhaust waste heat as a heat source of the cycle has been simulated in this study. An internal combustion engine with a volume of 1.3 liters at different engine speeds and throttle openings was examined experimentally and exhaust conditions such as flow rate and temperature were used as the input of the cycle. For engine speeds above 2000 rpm, there was no trouble and the evaporator temperature ranged from -0.4oC to -7.1oC. For 1500 rpm and 1000 rpm, the evaporator temperature did not reach the desired range of variations, which is the case in other reported researches. There is no available solution for the situations where the engine is running at low speed such as in traffic jam or idle condition. Therefore, a new generator was designed and simulated to solve this problem. The simulation results show that by using the modified generator, the heat transfer to the generator improves by 16.8% on average. Consequently, the cooling capacity increases by 4.7%. Therefore, the current diffusion absorption cycle is capable of performing well at the low engine speeds.</Abstract>
			<OtherAbstract Language="FA">A diffusion absorption refrigeration cycle as a car refrigerator, which uses the car exhaust waste heat as a heat source of the cycle has been simulated in this study. An internal combustion engine with a volume of 1.3 liters at different engine speeds and throttle openings was examined experimentally and exhaust conditions such as flow rate and temperature were used as the input of the cycle. For engine speeds above 2000 rpm, there was no trouble and the evaporator temperature ranged from -0.4oC to -7.1oC. For 1500 rpm and 1000 rpm, the evaporator temperature did not reach the desired range of variations, which is the case in other reported researches. There is no available solution for the situations where the engine is running at low speed such as in traffic jam or idle condition. Therefore, a new generator was designed and simulated to solve this problem. The simulation results show that by using the modified generator, the heat transfer to the generator improves by 16.8% on average. Consequently, the cooling capacity increases by 4.7%. Therefore, the current diffusion absorption cycle is capable of performing well at the low engine speeds.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Diffusion Absorption Refrigeration cycle</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Internal combustion engine</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Exhaust wasted heat</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Cooling Capacity</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Car refrigerator</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3075_a2186aa7c086b46ad4e8bf81e2a3a19b.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>11</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>A Novel Biomass-Driven Cogeneration System for Zero-Energy Buildings</ArticleTitle>
<VernacularTitle>A Novel Biomass-Driven Cogeneration System for Zero-Energy Buildings</VernacularTitle>
			<FirstPage>1443</FirstPage>
			<LastPage>1462</LastPage>
			<ELocationID EIdType="pii">3142</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14766.5942</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Kourosh</FirstName>
					<LastName>Javaherdeh</LastName>
<Affiliation>Instructor of Department of Mechanical Engineering, Faculty of Engineering, University of Guilan</Affiliation>
<Identifier Source="ORCID">0000-0002-1570-011X</Identifier>

</Author>
<Author>
					<FirstName>Fazel</FirstName>
					<LastName>Mohammadikhah</LastName>
<Affiliation>Phd student of mechanical engineering - faculty of ,mechanical engineering - university of guilan</Affiliation>

</Author>
<Author>
					<FirstName>Javad</FirstName>
					<LastName>MahmoudiMehr</LastName>
<Affiliation>gulian</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>08</Month>
					<Day>04</Day>
				</PubDate>
			</History>
		    <Abstract>This study proposes and evaluates a new cogeneration system for zero-energy buildings.The proposed system is comprised of a biomass gasifier, an internal combustion engine, a double-effectlithium bromide-water absorption chiller, a backup boiler for hot water production, a gas storage tank,a hot water storage tank, and two heat exchangers. The system is supposed to provide the building withthe electricity, hot water, heating and cooling requirements over the year. Besides presenting a functionalstrategy for the proposed system, this study evaluates the sensitivity of the objectives of the system (i.e.,annual actual benefit) to some main decision variables, including the capacity of engine, chiller andboiler, the volume of hot water tank, the start-up time of the internal combustion engine. The resultsdemonstrate that an increase in the input power of the engine helps to achieve the goal of zero-energybuildings. It is observed that the system is most economical when the cooling capacity of the absorptionchiller approaches the heating and cooling demands of the building. The results also indicate that thestart-up time of the combustion engine would be more influential in the case of high electricity demandconditions.</Abstract>
			<OtherAbstract Language="FA">This study proposes and evaluates a new cogeneration system for zero-energy buildings.The proposed system is comprised of a biomass gasifier, an internal combustion engine, a double-effectlithium bromide-water absorption chiller, a backup boiler for hot water production, a gas storage tank,a hot water storage tank, and two heat exchangers. The system is supposed to provide the building withthe electricity, hot water, heating and cooling requirements over the year. Besides presenting a functionalstrategy for the proposed system, this study evaluates the sensitivity of the objectives of the system (i.e.,annual actual benefit) to some main decision variables, including the capacity of engine, chiller andboiler, the volume of hot water tank, the start-up time of the internal combustion engine. The resultsdemonstrate that an increase in the input power of the engine helps to achieve the goal of zero-energybuildings. It is observed that the system is most economical when the cooling capacity of the absorptionchiller approaches the heating and cooling demands of the building. The results also indicate that thestart-up time of the combustion engine would be more influential in the case of high electricity demandconditions.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Biomass</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Zero energy building</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Economic analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sensitivity analysis</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3142_bd85282513da4089c441926e1975898c.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>02</Month>
					<Day>15</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Exergoeconomic Analysis of a Solid Oxide Fuel Cell Based Trigeneration System
with External Reformer and Dimethyl Ether</ArticleTitle>
<VernacularTitle>Exergoeconomic Analysis of a Solid Oxide Fuel Cell Based Trigeneration System
with External Reformer and Dimethyl Ether</VernacularTitle>
			<FirstPage>1463</FirstPage>
			<LastPage>1478</LastPage>
			<ELocationID EIdType="pii">3292</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15117.6030</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Soheila</FirstName>
					<LastName>Saleh Mirhasani</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Samad</FirstName>
					<LastName>Jafarmadar</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia,</Affiliation>

</Author>
<Author>
					<FirstName>Shahram</FirstName>
					<LastName>Khalilarya</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-6434-852X</Identifier>

</Author>
<Author>
					<FirstName>Ata</FirstName>
					<LastName>Chitsaz</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>10</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		    <Abstract>In the present study, Exergoeconomic analysis of a combined solid oxide fuel cell with  a gas turbine, a generator-absorber heat exchanger and heating process heat exchanger for heating, cooling and power production as a tri-generation system is conducted. An external steam reformer is applied to convert di-methyl ether as oxygenated fuel to hydrogen for the electrochemical process of the solid oxide fuel cell. The influence of the primary design parameters (fuel utilization factor and anode inlet temperature) on several variables (energy and exergy efficiencies, exergy destruction and unit costs of the power) are examined. Results show that energy efficiency of proposed system is 38% higher than standalone solid oxide fuel cell. It was found that the maximum exergy destructions occurred in afterburner, solid oxide fuel cell and recuperator. An increase in anode inlet temperature leads to reduction of exergy destruction in afterburner and fuelcell. Unit cost of power is equal to 23.51 $⁄GJ and decreases with an increase in fuel utilization factor or increasing of anode inlet temperature. Increasing of utilization factor will increase all exergy efficiencies by 12%. The effect of increase in anode inlet temperature on exergy efficiencies is positive but compared with the other parameter is lower and will increase them by 8%.</Abstract>
			<OtherAbstract Language="FA">In the present study, Exergoeconomic analysis of a combined solid oxide fuel cell with  a gas turbine, a generator-absorber heat exchanger and heating process heat exchanger for heating, cooling and power production as a tri-generation system is conducted. An external steam reformer is applied to convert di-methyl ether as oxygenated fuel to hydrogen for the electrochemical process of the solid oxide fuel cell. The influence of the primary design parameters (fuel utilization factor and anode inlet temperature) on several variables (energy and exergy efficiencies, exergy destruction and unit costs of the power) are examined. Results show that energy efficiency of proposed system is 38% higher than standalone solid oxide fuel cell. It was found that the maximum exergy destructions occurred in afterburner, solid oxide fuel cell and recuperator. An increase in anode inlet temperature leads to reduction of exergy destruction in afterburner and fuelcell. Unit cost of power is equal to 23.51 $⁄GJ and decreases with an increase in fuel utilization factor or increasing of anode inlet temperature. Increasing of utilization factor will increase all exergy efficiencies by 12%. The effect of increase in anode inlet temperature on exergy efficiencies is positive but compared with the other parameter is lower and will increase them by 8%.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Solid oxide fuel cell</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Dimethyl ether</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Tri-generation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">External reforming</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Exergoeconomic analysis</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3292_cfcce0621b49c983991ead4c3d4d3b6b.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>11</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Study of Temperature Distribution of H2/O2 Polymer Electrolyte Fuel Cell in Different Operating Conditions</ArticleTitle>
<VernacularTitle>Study of Temperature Distribution of H2/O2 Polymer Electrolyte Fuel Cell in Different Operating Conditions</VernacularTitle>
			<FirstPage>1479</FirstPage>
			<LastPage>1496</LastPage>
			<ELocationID EIdType="pii">3162</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14354.5842</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Seyyed Majid</FirstName>
					<LastName>Rahgoshay</LastName>
<Affiliation>School of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-6484-6190</Identifier>

</Author>
<Author>
					<FirstName>Ali Akbar</FirstName>
					<LastName>Ranjbar</LastName>
<Affiliation>School of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Abbas</FirstName>
					<LastName>Ramiar</LastName>
<Affiliation>School of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ebrahim</FirstName>
					<LastName>Alizadeh</LastName>
<Affiliation>School of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>04</Month>
					<Day>24</Day>
				</PubDate>
			</History>
		    <Abstract>The fuel cell is an electrochemical energy exchanger that directly converts the chemical energy into direct current and heat. Thermal management and water management are two major challenges in designing and efficiency of polymer fuel cells, which are inherent in each other. In this paper, by manufacture polymer electrolyte membrane fuel cell and test under different conditions, an analysis will be made of how the temperature is distributed in the full cell. By studding this temperature distribution, the relationship between power generation and heat distribution, thermal parameters (temperature distribution, maximum and minimum temperature) are extracted. The innovation aspect of this paper is to achieve an understanding of the distribution of temperature in polymeric fuel cell under different operating conditions. Also, the temperature distribution has been investigated in open-end and dead-end operating modes in different pressures and stoichiometries. When the fuel cell is changed from the open-end to the dead end mode, the maximum temperature changed from the outlet section in to the input section. By increasing pressure, the importance of maldistribution control and design of a suitable cooling system will increase.</Abstract>
			<OtherAbstract Language="FA">The fuel cell is an electrochemical energy exchanger that directly converts the chemical energy into direct current and heat. Thermal management and water management are two major challenges in designing and efficiency of polymer fuel cells, which are inherent in each other. In this paper, by manufacture polymer electrolyte membrane fuel cell and test under different conditions, an analysis will be made of how the temperature is distributed in the full cell. By studding this temperature distribution, the relationship between power generation and heat distribution, thermal parameters (temperature distribution, maximum and minimum temperature) are extracted. The innovation aspect of this paper is to achieve an understanding of the distribution of temperature in polymeric fuel cell under different operating conditions. Also, the temperature distribution has been investigated in open-end and dead-end operating modes in different pressures and stoichiometries. When the fuel cell is changed from the open-end to the dead end mode, the maximum temperature changed from the outlet section in to the input section. By increasing pressure, the importance of maldistribution control and design of a suitable cooling system will increase.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Thermal Imaging</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Polymer Electrolyte Membrane Fuel Cell</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">temperature distribution</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Operating Conditions</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Dead End Mode</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3162_d60678e8f2ba9c540798ebbde31177e8.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>15</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Investigation of Temperature Distribution During Dynamic Stress Test on the Surface of Lithium-ion Battery used in an Electric Hybrid Vehicle</ArticleTitle>
<VernacularTitle>Investigation of Temperature Distribution During Dynamic Stress Test on the Surface of Lithium-ion Battery used in an Electric Hybrid Vehicle</VernacularTitle>
			<FirstPage>1497</FirstPage>
			<LastPage>1512</LastPage>
			<ELocationID EIdType="pii">3230</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.14443.5862</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Gholam Reza</FirstName>
					<LastName>Molaeimanesh</LastName>
<Affiliation>School of Automotive Engineering, Iran University of Science and Technology, Tehran, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Seyed Morteza</FirstName>
					<LastName>Mousavi-khoshdel</LastName>
<Affiliation>Department of Chemistry, Iran University of Science and Technology</Affiliation>

</Author>
<Author>
					<FirstName>Amir Bahador</FirstName>
					<LastName>Nemati</LastName>
<Affiliation>School of Automotive Engineering, Iran University of Science and Technology</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>05</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		    <Abstract>There are two major challenges for today’s world: urban air pollution and the concern that fossil fuels will end, which forces humans to replace fossil fuels sources with renewable energy sources; the automobile industry can have a key role in tackling of both challenges. To overcome these challenges, during the last decade, the development of electric vehicles has been on the agenda for the automotive industry. Lithium-ion rechargeable batteries play a vital role in these vehicles. The performance, safety and life of these batteries are very much affected by their operating temperature. In this study, with the help of experimental data, a lithium-ion battery cell is simulated using the ANSYS Fluent software via a two-potential model. The time variations of the voltage and maximum cell temperature along with the temperature distribution at four constant discharge rates of 2C, 3C, 7C, and 9C and the discharge profile of dynamic stress test -which is a special profile used for testing hybrid vehicles battery systems- are presented. The simulation results indicate that high temperatures as 45 C are also experienced during the dynamic stress test. Such a temperature which could lead to a battery thermal runaway would be a hazard to the battery and electric vehicle.</Abstract>
			<OtherAbstract Language="FA">There are two major challenges for today’s world: urban air pollution and the concern that fossil fuels will end, which forces humans to replace fossil fuels sources with renewable energy sources; the automobile industry can have a key role in tackling of both challenges. To overcome these challenges, during the last decade, the development of electric vehicles has been on the agenda for the automotive industry. Lithium-ion rechargeable batteries play a vital role in these vehicles. The performance, safety and life of these batteries are very much affected by their operating temperature. In this study, with the help of experimental data, a lithium-ion battery cell is simulated using the ANSYS Fluent software via a two-potential model. The time variations of the voltage and maximum cell temperature along with the temperature distribution at four constant discharge rates of 2C, 3C, 7C, and 9C and the discharge profile of dynamic stress test -which is a special profile used for testing hybrid vehicles battery systems- are presented. The simulation results indicate that high temperatures as 45 C are also experienced during the dynamic stress test. Such a temperature which could lead to a battery thermal runaway would be a hazard to the battery and electric vehicle.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Air pollution</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">electric vehicles</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Renewable Energy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Lithium-ion batteries</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Battery simulation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3230_c12706a7c6e8d6476c3d2b6ae0042a82.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental Study and Economic Evaluation of a Cascade Solar Water Desalination Unit in Various Conditions</ArticleTitle>
<VernacularTitle>Experimental Study and Economic Evaluation of a Cascade Solar Water Desalination Unit in Various Conditions</VernacularTitle>
			<FirstPage>1513</FirstPage>
			<LastPage>1530</LastPage>
			<ELocationID EIdType="pii">3144</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14556.5887</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mohammad</FirstName>
					<LastName>Vafaie</LastName>
<Affiliation>departement mechanical engineering, Ferdowsi university of Mashhad</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad</FirstName>
					<LastName>Barzgarnezhad</LastName>
<Affiliation>Mechanical Engineering Departement, Bozorgmehr University od Qaenat, Qaen, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ali</FirstName>
					<LastName>Arbabi</LastName>
<Affiliation>Mechanical Engineering Departement, Bozorgmehr University od Qaenat, Qaen, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ehsan</FirstName>
					<LastName>Shakib</LastName>
<Affiliation>Mechanical Engineering Departement, Bozorgmehr University od Qaenat, Qaen, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad Mustafa</FirstName>
					<LastName>Ghafurian</LastName>
<Affiliation>Department of Mechanical Engineering
Ferdowsi University Of Mashhad (FUM)</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>05</Day>
				</PubDate>
			</History>
		    <Abstract>Lack of freshwater as a major crisis in the world and an attempt to find a solution is one of the most important debates in the world that has attracted many researchers. In this paper, a cascade solar desalination unit with external reflector has built and experimented in eight days. In order to increase the production of fresh water, various techniques were applied such as 1) installing a number of fins on the stairs and on the waterway to create hot spots, 2) use of internal reflectors at the base of the stairs and 3) use of an external condenser for increasing condensation rate of produced vapor. Then, the system was experimented in eight configuration using combination of above techniques that the experimental results were presented as well as the results of economic analysis. The results showed use of the fins led to the most amount of fresh water although the rest of techniques significantly increased the product. It is worth mentioning that use of the fins led to fresh water with the lowest cost of product in value of 1341.5 Rials/lit. On the other hand, the system with an external condenser had the maximum efficiency and the system with the fins has the third place among the eight study configuration.</Abstract>
			<OtherAbstract Language="FA">Lack of freshwater as a major crisis in the world and an attempt to find a solution is one of the most important debates in the world that has attracted many researchers. In this paper, a cascade solar desalination unit with external reflector has built and experimented in eight days. In order to increase the production of fresh water, various techniques were applied such as 1) installing a number of fins on the stairs and on the waterway to create hot spots, 2) use of internal reflectors at the base of the stairs and 3) use of an external condenser for increasing condensation rate of produced vapor. Then, the system was experimented in eight configuration using combination of above techniques that the experimental results were presented as well as the results of economic analysis. The results showed use of the fins led to the most amount of fresh water although the rest of techniques significantly increased the product. It is worth mentioning that use of the fins led to fresh water with the lowest cost of product in value of 1341.5 Rials/lit. On the other hand, the system with an external condenser had the maximum efficiency and the system with the fins has the third place among the eight study configuration.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">SOLAR DESALINATION</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">TECHNIQUES FOR INCREASING PRODUCT</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ECONOMICAL EVALUATION</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">EFFICIENCY</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">COST OF PRODUCT</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3144_a41b3bb3e6b050b6c9067c67f663b915.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>05</Month>
					<Day>26</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Thermoeconomic Analysis of a Double Slope Basin Solar Still Equipped to Phase Change Material and Photovoltaic Thermal Collector</ArticleTitle>
<VernacularTitle>Thermoeconomic Analysis of a Double Slope Basin Solar Still Equipped to Phase Change Material and Photovoltaic Thermal Collector</VernacularTitle>
			<FirstPage>1531</FirstPage>
			<LastPage>1550</LastPage>
			<ELocationID EIdType="pii">2921</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14032.5784</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Erfan</FirstName>
					<LastName>Hedayati-Mehdiabadi</LastName>
<Affiliation>Department of Mechanical Engineering, University of Sistan and Baluchestan, Zahedan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Faramarz</FirstName>
					<LastName>Sarhaddi</LastName>
<Affiliation>Head of Department of Mechanical Engineering
Research Laboratory of Renewable Energies and Electromagnetic Fluids, Department of Mechanical Engineering, University of Sistan and Baluchestan, Zahedan, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-5216-9823</Identifier>

</Author>
<Author>
					<FirstName>Fatemeh</FirstName>
					<LastName>Sobhnamayan</LastName>
<Affiliation>Department of Mechanical Engineering, University of Sistan and Baluchestan, Zahedan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>02</Month>
					<Day>01</Day>
				</PubDate>
			</History>
		    <Abstract>In present study the thermoeconomic analysis of a double slope basin solar still equipped to phase change material and photovoltaic thermal collector is carried out. The governing equations of problem are obtained by writing energy balance for different components of the system. The goal of governing equations solution is the calculation of glass cover temperature, absorber temperature, saline water temperature, phase change material temperature, freshwater productivity and the useful heat gain of photovoltaic thermal collector. Also, the output electrical power of photovoltaic module is calculated by four parameters current-voltage model. Present study numerical results are in good agreement with experimental data. The system performance evaluation is carried out from the viewpoint of freshwater productivity and energy efficiency for the sample winter and summer day of Zahedan. Results show that the freshwater productivity increases to 10.6% by increasing of mass flow rate from 0.001 to 0.01 kg/s. Increase of saline water mass of basin from 20 to 30 kg decreases the freshwater productivity to 4.8% during the day. On the other hand, it increases the freshwater productivity to 7.43% during the night. The energy efficiency is 37.5% less on winter day than summer day. The freshwater production cost is obtained 0.0314 $/l.m2.</Abstract>
			<OtherAbstract Language="FA">In present study the thermoeconomic analysis of a double slope basin solar still equipped to phase change material and photovoltaic thermal collector is carried out. The governing equations of problem are obtained by writing energy balance for different components of the system. The goal of governing equations solution is the calculation of glass cover temperature, absorber temperature, saline water temperature, phase change material temperature, freshwater productivity and the useful heat gain of photovoltaic thermal collector. Also, the output electrical power of photovoltaic module is calculated by four parameters current-voltage model. Present study numerical results are in good agreement with experimental data. The system performance evaluation is carried out from the viewpoint of freshwater productivity and energy efficiency for the sample winter and summer day of Zahedan. Results show that the freshwater productivity increases to 10.6% by increasing of mass flow rate from 0.001 to 0.01 kg/s. Increase of saline water mass of basin from 20 to 30 kg decreases the freshwater productivity to 4.8% during the day. On the other hand, it increases the freshwater productivity to 7.43% during the night. The energy efficiency is 37.5% less on winter day than summer day. The freshwater production cost is obtained 0.0314 $/l.m2.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Double slope basin solar still</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">energy analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Economic analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Photovoltaic thermal collector</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Phase change material</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_2921_17d8da815fa21c57af9829fb0a869602.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>15</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Using Polyethylene Glycol, as a Phase Change Material and Fins for the Cooling of Photovoltaic Cells of the Crystalline Type</ArticleTitle>
<VernacularTitle>Using Polyethylene Glycol, as a Phase Change Material and Fins for the Cooling of Photovoltaic Cells of the Crystalline Type</VernacularTitle>
			<FirstPage>1551</FirstPage>
			<LastPage>1560</LastPage>
			<ELocationID EIdType="pii">3229</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.14777.5949</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mohammad</FirstName>
					<LastName>Firoozzadeh</LastName>
<Affiliation>Department of Mechanical Engineering, Faculty of Mechanical Engineering, Jundi-Shapur University of technology, Dezful, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Amir Hossein</FirstName>
					<LastName>Shiravi</LastName>
<Affiliation>Department of Mechanical Engineering, Faculty of Mechanical engineering, Jundi-Shapur University of technology, Dezful, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mojtaba</FirstName>
					<LastName>Shafiee</LastName>
<Affiliation>Department of Chemical Engineering, Faculty of Chemical Engineering, Jundi-Shapur University of Technology, Dezful, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>08</Month>
					<Day>08</Day>
				</PubDate>
			</History>
		    <Abstract>Photovoltaic (PV) technology is one of the most popular methods to produce power. In hot days of the year, when the maximum irradiation of sun is available, the efficiency of PV cells falls down and the cells must be kept cool. In this paper, Polyethylene-Glycol 600 (PEG-600) is used as a phase change material (PCM) is in order to decrease the temperature of PV cells. Moreover, to enhance the heat transfer rate, adding some fins was investigated. The panel equipped with PCM, reached the same temperature as the conventional panel at the last 80 mins of the test, nevertheless, the panel equipped with both PCM and fins, at the end of the experiment, had still about 9°C temperature difference compared with the conventional panel. Furthermore, the maximum efficiency difference between the conventional panel and the one with PCM and the panel with PCM + fins, were about 2.4 % and 4.6 %, respectively. This means that adding fins, plays an important role to increase the efficiency by controlling the cell temperature due to increase the heat exchange between the panel and PCM. Finally, an economical assessment is also presented to verify the industrial feasibility of the proposed prototypes.</Abstract>
			<OtherAbstract Language="FA">Photovoltaic (PV) technology is one of the most popular methods to produce power. In hot days of the year, when the maximum irradiation of sun is available, the efficiency of PV cells falls down and the cells must be kept cool. In this paper, Polyethylene-Glycol 600 (PEG-600) is used as a phase change material (PCM) is in order to decrease the temperature of PV cells. Moreover, to enhance the heat transfer rate, adding some fins was investigated. The panel equipped with PCM, reached the same temperature as the conventional panel at the last 80 mins of the test, nevertheless, the panel equipped with both PCM and fins, at the end of the experiment, had still about 9°C temperature difference compared with the conventional panel. Furthermore, the maximum efficiency difference between the conventional panel and the one with PCM and the panel with PCM + fins, were about 2.4 % and 4.6 %, respectively. This means that adding fins, plays an important role to increase the efficiency by controlling the cell temperature due to increase the heat exchange between the panel and PCM. Finally, an economical assessment is also presented to verify the industrial feasibility of the proposed prototypes.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Phase change material</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Photovoltaic</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">fin</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">economical feasibility</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3229_85ae750ad1dbdc5c2703bcfe97e77152.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>09</Month>
					<Day>11</Day>
				</PubDate>
			</Journal>
<ArticleTitle>An Experimental Investigation of Convective Heat Transfer of Slurry Phase Change Material in a Tube with  Butterfly Tube Inserts</ArticleTitle>
<VernacularTitle>An Experimental Investigation of Convective Heat Transfer of Slurry Phase Change Material in a Tube with  Butterfly Tube Inserts</VernacularTitle>
			<FirstPage>1561</FirstPage>
			<LastPage>1576</LastPage>
			<ELocationID EIdType="pii">3068</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14356.5843</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mostafa</FirstName>
					<LastName>Moshtagh</LastName>
<Affiliation>Faculty of Petroleum, Gas and Petrochemical Engineering, Persian Gulf University</Affiliation>

</Author>
<Author>
					<FirstName>Ahmad</FirstName>
					<LastName>Jamekhorshid</LastName>
<Affiliation>Faculty of Petroleum, Gas and Petrochemical Engineering, Persian Gulf University, Bushehr</Affiliation>
<Identifier Source="ORCID">0000-0001-8262-4957</Identifier>

</Author>
<Author>
					<FirstName>Ahmad</FirstName>
					<LastName>Azari</LastName>
<Affiliation>Assistant Professor of Chemical Engineering/ Persian Gulf University</Affiliation>
<Identifier Source="ORCID">0000-0001-8878-947X</Identifier>

</Author>
<Author>
					<FirstName>Hassan</FirstName>
					<LastName>Bazai</LastName>
<Affiliation>Faculty of Petroleum, Gas and Petrochemical Engineering, Persian Gulf University</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>04</Month>
					<Day>24</Day>
				</PubDate>
			</History>
		    <Abstract>In this study, the effect of adding of microencapsulated phase change material to pure water base fluid as a working fluid was investigated. To this end, a laboratory apparatus was prepared and used. The main part of this setup is a tube which is called test section. The test section has a circular cross- section under a constant heat flux and is equipped with 6 thermocouples for measuring wall temperature at 6 different points as well as 2 thermocouples to measure the inlet and outlet flow temperature into the tube. The effect of butterfly tube inserts was also studied and the results were compared with each other. The results indicated that adding phase change material to base fluid could improve the heat transfer rate up to 41%. In addition, when the butterfly blades were placed in the test section, it was observed that the heat transfer rate increased to 234% for pure water and up to 180% for the slurry with 10 wt% of microencapsulated phase change material. The blades increased heat transfer by creating turbulence in the flow and eliminating the thermal boundary layer.</Abstract>
			<OtherAbstract Language="FA">In this study, the effect of adding of microencapsulated phase change material to pure water base fluid as a working fluid was investigated. To this end, a laboratory apparatus was prepared and used. The main part of this setup is a tube which is called test section. The test section has a circular cross- section under a constant heat flux and is equipped with 6 thermocouples for measuring wall temperature at 6 different points as well as 2 thermocouples to measure the inlet and outlet flow temperature into the tube. The effect of butterfly tube inserts was also studied and the results were compared with each other. The results indicated that adding phase change material to base fluid could improve the heat transfer rate up to 41%. In addition, when the butterfly blades were placed in the test section, it was observed that the heat transfer rate increased to 234% for pure water and up to 180% for the slurry with 10 wt% of microencapsulated phase change material. The blades increased heat transfer by creating turbulence in the flow and eliminating the thermal boundary layer.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Convective Heat Transfer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Slurry phase change material</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Butterfly Tube Inserts</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal energy storage</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heat exchanger</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3068_f5496252609c43eb8a3d147ab9b9c006.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>The Experimental Analyses of Grooved Surface and Magnetic Field Effects on γ-Fe2O3/water Nanofluid Pool Boiling</ArticleTitle>
<VernacularTitle>The Experimental Analyses of Grooved Surface and Magnetic Field Effects on γ-Fe2O3/water Nanofluid Pool Boiling</VernacularTitle>
			<FirstPage>1577</FirstPage>
			<LastPage>1594</LastPage>
			<ELocationID EIdType="pii">3145</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14668.5911</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Sanaz</FirstName>
					<LastName>Nasiri</LastName>
<Affiliation>Mechanical Engineering/Yazd University/Yazd/Iran</Affiliation>

</Author>
<Author>
					<FirstName>Shahram</FirstName>
					<LastName>Talebi</LastName>
<Affiliation>Mechanical Engineering/Yazd University</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad Reza</FirstName>
					<LastName>Salimpour</LastName>
<Affiliation>Professor/Isfahan University of Technology</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>30</Day>
				</PubDate>
			</History>
		    <Abstract>Use of nanoparticle, heater surface expansion and magnetic field applying are important and effective elements on boiling heat transfer. In this article, pool boiling of deionized water and γ-Fe2O3/water nanofluid have been analyzed on smooth and copper grooved surface at one atmosphere pressure in the presence and absence of magnetic field, experimentally. The result showed that the boiling heat transfer coefficient of deionized water has increased in circular and rectangular grooved surfaces and has decreased in triangular grooved surface toward the smooth surface. The boiling heat transfer coefficient of nanofluid has increased 24% in circular grooved surface and has decreased 8% and 37% in rectangular and 37% in triangular grooved surfaces. The corners existence and wettability reduction in vertical wall of rectangular and triangular grooves and the bubbles slipping cause thermal resistance increasing toward circle groove. Two flat constant magnets have been used in two sides of boiling reservoir for magnetic field creation. By applying magnetic field with negative gradient, the boiling heat transfer coefficient of nanofluid has enhanced in circular and rectangular grooved surfaces and has reduced in triangular grooved surface. The upward magnetic force causes the formed bubbles diameter decreasing, but groove type is effective on result, too.</Abstract>
			<OtherAbstract Language="FA">Use of nanoparticle, heater surface expansion and magnetic field applying are important and effective elements on boiling heat transfer. In this article, pool boiling of deionized water and γ-Fe2O3/water nanofluid have been analyzed on smooth and copper grooved surface at one atmosphere pressure in the presence and absence of magnetic field, experimentally. The result showed that the boiling heat transfer coefficient of deionized water has increased in circular and rectangular grooved surfaces and has decreased in triangular grooved surface toward the smooth surface. The boiling heat transfer coefficient of nanofluid has increased 24% in circular grooved surface and has decreased 8% and 37% in rectangular and 37% in triangular grooved surfaces. The corners existence and wettability reduction in vertical wall of rectangular and triangular grooves and the bubbles slipping cause thermal resistance increasing toward circle groove. Two flat constant magnets have been used in two sides of boiling reservoir for magnetic field creation. By applying magnetic field with negative gradient, the boiling heat transfer coefficient of nanofluid has enhanced in circular and rectangular grooved surfaces and has reduced in triangular grooved surface. The upward magnetic force causes the formed bubbles diameter decreasing, but groove type is effective on result, too.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Pool boiling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">magnetic nanofluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">grooved surface</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heat transfer coefficient</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">magnetic field</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3145_1160453108d3e537255e9f7b931f4e90.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental Investigation and Visualization of Flow Boiling Heat Transfer in a Vertical Tube Containing Metal Porous Medium</ArticleTitle>
<VernacularTitle>Experimental Investigation and Visualization of Flow Boiling Heat Transfer in a Vertical Tube Containing Metal Porous Medium</VernacularTitle>
			<FirstPage>1595</FirstPage>
			<LastPage>1612</LastPage>
			<ELocationID EIdType="pii">3202</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14539.5880</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mahdi</FirstName>
					<LastName>Kashi</LastName>
<Affiliation>Shahrood Univ.</Affiliation>

</Author>
<Author>
					<FirstName>Amir</FirstName>
					<LastName>Ramezani</LastName>
<Affiliation>Shahrood Univ</Affiliation>

</Author>
<Author>
					<FirstName>Mohsen</FirstName>
					<LastName>Nazari</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>MM</FirstName>
					<LastName>Shahmardan</LastName>
<Affiliation>SUT</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>01</Day>
				</PubDate>
			</History>
		    <Abstract>In this study, flow boiling heat transfer in a vertical copper tube with internal diameter of 16 mm under constant heat flux conditions and at atmospheric pressure is experimentally investigated by using water as working fluid. All two-phase experiments are within the Slug flow regime which are visualized by a glass tube placed at the end of the laboratory bed and a high-speed camera. Heat transfer parameters such as Nusselt number and convection heat transfer coefficients are measured in different mass flow rates and heat fluxes. The results of the experiments are compared with the experimental data for the two-phase flow and the amount of deviation of the results from the proposed relationships is reported. Also, the effects of porous material, heat flux and mass flux on heat transfer parameters are investigated. It was also found that, despite the use of metal foam, the slug flow pattern remains in the porous tube.</Abstract>
			<OtherAbstract Language="FA">In this study, flow boiling heat transfer in a vertical copper tube with internal diameter of 16 mm under constant heat flux conditions and at atmospheric pressure is experimentally investigated by using water as working fluid. All two-phase experiments are within the Slug flow regime which are visualized by a glass tube placed at the end of the laboratory bed and a high-speed camera. Heat transfer parameters such as Nusselt number and convection heat transfer coefficients are measured in different mass flow rates and heat fluxes. The results of the experiments are compared with the experimental data for the two-phase flow and the amount of deviation of the results from the proposed relationships is reported. Also, the effects of porous material, heat flux and mass flux on heat transfer parameters are investigated. It was also found that, despite the use of metal foam, the slug flow pattern remains in the porous tube.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Two-phase heat transfer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">flow boiling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Metal foam</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">vertical flow</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">visualization</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3202_7486cef2522ee03547cfb970a404a874.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>07</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental Analysis of a Gas-Tank Water Heater with Porous Burner</ArticleTitle>
<VernacularTitle>Experimental Analysis of a Gas-Tank Water Heater with Porous Burner</VernacularTitle>
			<FirstPage>1613</FirstPage>
			<LastPage>1626</LastPage>
			<ELocationID EIdType="pii">1197</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2017.12702.5401</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Seyed Abdolmehdi</FirstName>
					<LastName>Hashemi</LastName>
<Affiliation></Affiliation>
<Identifier Source="ORCID">0000-0001-7169-7173</Identifier>

</Author>
<Author>
					<FirstName>Ahmadreza</FirstName>
					<LastName>Tayyareh</LastName>
<Affiliation>Department of Mechanical Engineering, University of Kashan, Kashan, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Mahdi</FirstName>
					<LastName>Mollamahdi</LastName>
<Affiliation>Department of Mechanical Engineering, University of Kashan, Kashan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2017</Year>
					<Month>03</Month>
					<Day>28</Day>
				</PubDate>
			</History>
		    <Abstract>In this study, the effects of the porous burners and the conventional burner on the performance of gas-tank water heater have been investigated experimentally. In this experiment, a partially premixed burner with natural gas fuel is used. Four different types of the porous medium have been applied. In the Results, water temperature, flue temperature, flame temperature, emissions and combustion efficiency for different burners at various flow rates of fuel have been reported. Observation shows that the use of porous burner with 10 cm porous medium reduces the time that water temperature reaches 60 oC. Also observed that the conventional burner has the lowest flame temperature and the highest flue temperature in all of the tests. Moreover, it is showed that the burners with 10 and 5 cm porous medium have the highest flame temperature and the lowest flue temperature in all of the tests, respectively. The burner with 5 cm porous medium and conventional burner have the highest and lowest amount of carbon dioxide in all of the tests, respectively. Also, the combustion efficiency of gas-tank water heater increases about 15 percent by using the burner with 10 cm porous medium.</Abstract>
			<OtherAbstract Language="FA">In this study, the effects of the porous burners and the conventional burner on the performance of gas-tank water heater have been investigated experimentally. In this experiment, a partially premixed burner with natural gas fuel is used. Four different types of the porous medium have been applied. In the Results, water temperature, flue temperature, flame temperature, emissions and combustion efficiency for different burners at various flow rates of fuel have been reported. Observation shows that the use of porous burner with 10 cm porous medium reduces the time that water temperature reaches 60 oC. Also observed that the conventional burner has the lowest flame temperature and the highest flue temperature in all of the tests. Moreover, it is showed that the burners with 10 and 5 cm porous medium have the highest flame temperature and the lowest flue temperature in all of the tests, respectively. The burner with 5 cm porous medium and conventional burner have the highest and lowest amount of carbon dioxide in all of the tests, respectively. Also, the combustion efficiency of gas-tank water heater increases about 15 percent by using the burner with 10 cm porous medium.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Experimental study</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Porous burner</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Gas-tank water heater</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Combustion efficiency</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_1197_ae5e3ce40e0404a45ecacaaf05e5f735.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical Investigation of Fin Position Effect on the Forced Convection Heat Transfer Inside a Channel in Turbulent Flow</ArticleTitle>
<VernacularTitle>Numerical Investigation of Fin Position Effect on the Forced Convection Heat Transfer Inside a Channel in Turbulent Flow</VernacularTitle>
			<FirstPage>1627</FirstPage>
			<LastPage>1640</LastPage>
			<ELocationID EIdType="pii">3244</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.14559.5885</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Alavi Lavsani</LastName>
<Affiliation>Department od mechanical engineering, pardis branch, islamic azad university</Affiliation>

</Author>
<Author>
					<FirstName>Mohsen</FirstName>
					<LastName>Pirmohammadi</LastName>
<Affiliation>mechanical engineering, pardis branch, islamic azad university</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>04</Day>
				</PubDate>
			</History>
		    <Abstract>The using of fins for convection heat transfer enhancement is one of the effective approaches of heat transfer enhancement in a 2 dimensional channels. In this investigation, five different geometries for fins have been considered; numerical results were presented for fluid flow variables and heat transfer. For this purpose, governing equations of fluid flow and heat transfer were discretized with finite volume method; also for linking of velocity and pressure of fluid flow, SIMPLE algorithm was employed. Turbulent flow modelling was applied by turbulent model. Sensitivity of numerical results from computational grid and validation of numerical results were provided in compare of experimental and other numerical investigation. Then, geometries were investigated for fins include of triangle with different angle, trapezoidal and square. For these geometries, numerical results for velocity vector, pressure drop and temperature of fluid have been presented. Finally, heat transfer results were studied with regards to Nusselt number. Triangle fin with angle of 60 degrees respect to angle of 90 degrees has more Nusselt number and trapezoidal fin has much Nusselt number among five studied fins. From the investigation of the heat transfer to pressure drop ratio, it was observed that the trapezoidal fins have the best performance.</Abstract>
			<OtherAbstract Language="FA">The using of fins for convection heat transfer enhancement is one of the effective approaches of heat transfer enhancement in a 2 dimensional channels. In this investigation, five different geometries for fins have been considered; numerical results were presented for fluid flow variables and heat transfer. For this purpose, governing equations of fluid flow and heat transfer were discretized with finite volume method; also for linking of velocity and pressure of fluid flow, SIMPLE algorithm was employed. Turbulent flow modelling was applied by turbulent model. Sensitivity of numerical results from computational grid and validation of numerical results were provided in compare of experimental and other numerical investigation. Then, geometries were investigated for fins include of triangle with different angle, trapezoidal and square. For these geometries, numerical results for velocity vector, pressure drop and temperature of fluid have been presented. Finally, heat transfer results were studied with regards to Nusselt number. Triangle fin with angle of 60 degrees respect to angle of 90 degrees has more Nusselt number and trapezoidal fin has much Nusselt number among five studied fins. From the investigation of the heat transfer to pressure drop ratio, it was observed that the trapezoidal fins have the best performance.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">heat transfer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Force Convection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fin position</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Finite volume method</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Turbulent flow</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3244_88e1ce84f9feef5a08d0df0334c53468.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical Investigation of the Effect of Coolant Injection Angle on the Pulsed Film Cooling Effectiveness of Square Wave Flow on Flat Plate</ArticleTitle>
<VernacularTitle>Numerical Investigation of the Effect of Coolant Injection Angle on the Pulsed Film Cooling Effectiveness of Square Wave Flow on Flat Plate</VernacularTitle>
			<FirstPage>1641</FirstPage>
			<LastPage>1658</LastPage>
			<ELocationID EIdType="pii">3201</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14746.5928</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Seyyed Mehdi</FirstName>
					<LastName>Hosseini Baghdad Abadi</LastName>
<Affiliation>energy transfer,mechanical engineering,semnan university,semnan,iran</Affiliation>
<Identifier Source="ORCID">0000-0002-0589-597X</Identifier>

</Author>
<Author>
					<FirstName>Saadat</FirstName>
					<LastName>Zirak</LastName>
<Affiliation>Mechanical Engineering Department, Semnan University</Affiliation>

</Author>
<Author>
					<FirstName>Mehran</FirstName>
					<LastName>Rajabi Zargarabadi</LastName>
<Affiliation>Department of mechanical engineering</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>07</Month>
					<Day>24</Day>
				</PubDate>
			</History>
		    <Abstract>The effect of the angle of injection on the film cooling effectiveness with square wave pulsation is investigated at various frequencies. Four angles of injection are selected at 20, 25, 30 and 35 degrees. Film cooling is used to cool turbine blades and extend the life of blade. The pulsed flow is investigated at three frequencies of 2, 50 and 500 Hz. Finite volume method is used to solve the flow governing equations. The shear stress transport k-ω model is used to model the turbulence. The obtained results showed that the injection angle of 20 to 25 degrees had the most film cooling effectiveness for all frequencies. In higher frequency, 500 Hz, it is observed an increase in the effectiveness of the film cooling in close distances after the injection holes. At far distances, the lower frequency, 2 Hz, produces the most effectiveness. The largest difference in centerline effectiveness is achieved at 500 Hz for hole angles of 20 to 35 degrees with a value of 64.3%. This value is 98.9% for lateral effectiveness. As the frequency increases, the cooling mass flow interruptions are reduced, and as a result, the instantaneous effectiveness shows a slower variation than the lower frequencies. The blowing ratio of 0.5 had the most value in comparison with the blowing ratio of 0.75 and 1 in all angles and frequencies. The maximum difference in effectiveness is 187.4% for blowing ratio of 0.5, in comparison with the other two blowing ratios.</Abstract>
			<OtherAbstract Language="FA">The effect of the angle of injection on the film cooling effectiveness with square wave pulsation is investigated at various frequencies. Four angles of injection are selected at 20, 25, 30 and 35 degrees. Film cooling is used to cool turbine blades and extend the life of blade. The pulsed flow is investigated at three frequencies of 2, 50 and 500 Hz. Finite volume method is used to solve the flow governing equations. The shear stress transport k-ω model is used to model the turbulence. The obtained results showed that the injection angle of 20 to 25 degrees had the most film cooling effectiveness for all frequencies. In higher frequency, 500 Hz, it is observed an increase in the effectiveness of the film cooling in close distances after the injection holes. At far distances, the lower frequency, 2 Hz, produces the most effectiveness. The largest difference in centerline effectiveness is achieved at 500 Hz for hole angles of 20 to 35 degrees with a value of 64.3%. This value is 98.9% for lateral effectiveness. As the frequency increases, the cooling mass flow interruptions are reduced, and as a result, the instantaneous effectiveness shows a slower variation than the lower frequencies. The blowing ratio of 0.5 had the most value in comparison with the blowing ratio of 0.75 and 1 in all angles and frequencies. The maximum difference in effectiveness is 187.4% for blowing ratio of 0.5, in comparison with the other two blowing ratios.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Pulse film cooling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">square wave flow</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">angle of injection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Shear stress transport k-ω turbu- lence model</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Frequency</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3201_24ec8468b67314c2013d215b77034476.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>19</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Shape Optimization of Supersonic Ejector to Enhance its Performance in Refrigeration Applications</ArticleTitle>
<VernacularTitle>Shape Optimization of Supersonic Ejector to Enhance its Performance in Refrigeration Applications</VernacularTitle>
			<FirstPage>1659</FirstPage>
			<LastPage>1674</LastPage>
			<ELocationID EIdType="pii">3192</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14672.5910</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Farid</FirstName>
					<LastName>Aligolzadeh</LastName>
<Affiliation>MSc student, Sharif University of Technology</Affiliation>

</Author>
<Author>
					<FirstName>Ali</FirstName>
					<LastName>Hakkaki-Fard</LastName>
<Affiliation>Mechanical Engineering/Sharif University/Assistant Professor</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		    <Abstract>Due to an increasing need for refrigeration systems and their growing electrical demand and greenhouse gases production, using ejector refrigeration systems would be a suitable substitution for conventional cooling systems. Main drawback of ejector refrigeration systems is their low coefficient of performance. The key component to improve the cycle performance is the ejector. Prerequisite of improving ejector performance is an accurate computational fluid dynamics simulation for predicting its entrainment ratio. In this study, a two dimensional, axisymmetric, steady state, compressible flow computational fluid dynamics simulation of a supersonic ejector is performed. In the second part of this study, geometrical optimization of the simulated ejector for two different objective functions is performed. The first objective function considered was the ejector entrainment ratio. The optimization with this objective function led to 53% relative improvement in the entrainment ratio with a negligible decrease in critical pressure. The second, objective function considered was the exergy efficiency in which the optimization showed 39.6% relative improvement. The exergy efficiency is used for the first time in the literature as the objective function for optimization of ejector geometry.</Abstract>
			<OtherAbstract Language="FA">Due to an increasing need for refrigeration systems and their growing electrical demand and greenhouse gases production, using ejector refrigeration systems would be a suitable substitution for conventional cooling systems. Main drawback of ejector refrigeration systems is their low coefficient of performance. The key component to improve the cycle performance is the ejector. Prerequisite of improving ejector performance is an accurate computational fluid dynamics simulation for predicting its entrainment ratio. In this study, a two dimensional, axisymmetric, steady state, compressible flow computational fluid dynamics simulation of a supersonic ejector is performed. In the second part of this study, geometrical optimization of the simulated ejector for two different objective functions is performed. The first objective function considered was the ejector entrainment ratio. The optimization with this objective function led to 53% relative improvement in the entrainment ratio with a negligible decrease in critical pressure. The second, objective function considered was the exergy efficiency in which the optimization showed 39.6% relative improvement. The exergy efficiency is used for the first time in the literature as the objective function for optimization of ejector geometry.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">computational fluid dynamics</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Supersonic ejector</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Shape optimization</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Entrainment ratio</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Exergy efficiency</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3192_766e428d1e232bbdd58664b41346196c.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>11</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluation of the Impact of Fan Coil Airflow Velocity on the Micron Particles Distribution in the Human Breathing Zone</ArticleTitle>
<VernacularTitle>Evaluation of the Impact of Fan Coil Airflow Velocity on the Micron Particles Distribution in the Human Breathing Zone</VernacularTitle>
			<FirstPage>1675</FirstPage>
			<LastPage>1686</LastPage>
			<ELocationID EIdType="pii">3127</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14319.5835</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Morteza</FirstName>
					<LastName>Taheri</LastName>
<Affiliation>Department of mechanical engineering, University of Birjand</Affiliation>

</Author>
<Author>
					<FirstName>Alireza</FirstName>
					<LastName>Zolfaghari</LastName>
<Affiliation>University of Birjand</Affiliation>
<Identifier Source="ORCID">0000-0001-9917-3400</Identifier>

</Author>
<Author>
					<FirstName>Hasan</FirstName>
					<LastName>Hasanzadeh</LastName>
<Affiliation>Faculty member of Birjand university</Affiliation>

</Author>
<Author>
					<FirstName>Mazyar</FirstName>
					<LastName>Salmanzadeh</LastName>
<Affiliation>Shahid Bahonar University of Kerman</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>04</Month>
					<Day>12</Day>
				</PubDate>
			</History>
		    <Abstract>Nowadays, most people spend their time in the interior spaces. Therefore, particulate pollutants in these spaces are serious threat to the human health. Hence, the investigation on distribution and deposition of particle pollutants in indoor spaces is important for assessing the indoor air quality. Due to the wide use of heating/cooling fan coils in the buildings, the effect of fan coil airflow velocity on the concentration of micron particles of 1, 10 and 100 microns in the breathing zone of seating (0.9 to 1.1 m) and standing (1.5 to 1.7 m) people has been studied in this article. For this purpose, by using the computational fluid dynamics and a developed code by the authors in OpenFOAM, the particle concentration is investigated in a room with a fan coil airflow velocity at 1.5 and 3 m/s. The results show that the large particles (100 microns) have not a significant effect on air quality and they settle down after about 10 seconds. In the other hand, the smaller particles (10 and 1 micron) have a major impact on ventilation conditions and they settle down after about 800 seconds. The results indicate that the fan coil velocity increases, also the results show that more particles are filtered by the filter in the fan coil by increasing fan coil velocity and the percentage of particles deposited on the floor reduced. For example, for 10 microns particles, by increasing fan coil velocity from 1.5 to 3 m/s, the percentage of deposited particles on the floor is reduced from 26% to 17%.</Abstract>
			<OtherAbstract Language="FA">Nowadays, most people spend their time in the interior spaces. Therefore, particulate pollutants in these spaces are serious threat to the human health. Hence, the investigation on distribution and deposition of particle pollutants in indoor spaces is important for assessing the indoor air quality. Due to the wide use of heating/cooling fan coils in the buildings, the effect of fan coil airflow velocity on the concentration of micron particles of 1, 10 and 100 microns in the breathing zone of seating (0.9 to 1.1 m) and standing (1.5 to 1.7 m) people has been studied in this article. For this purpose, by using the computational fluid dynamics and a developed code by the authors in OpenFOAM, the particle concentration is investigated in a room with a fan coil airflow velocity at 1.5 and 3 m/s. The results show that the large particles (100 microns) have not a significant effect on air quality and they settle down after about 10 seconds. In the other hand, the smaller particles (10 and 1 micron) have a major impact on ventilation conditions and they settle down after about 800 seconds. The results indicate that the fan coil velocity increases, also the results show that more particles are filtered by the filter in the fan coil by increasing fan coil velocity and the percentage of particles deposited on the floor reduced. For example, for 10 microns particles, by increasing fan coil velocity from 1.5 to 3 m/s, the percentage of deposited particles on the floor is reduced from 26% to 17%.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Indoor air quality</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Particulate pollutants</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Breathing zone</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fan coil</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Micron particles</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3127_ca1d3153a1cf0ed998d4879fbb50d9ab.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>19</Day>
				</PubDate>
			</Journal>
<ArticleTitle>The Solution of the Transient Diffusion-Radiation Binary Gas mixture Problem in Low Pressure Values between Two Flat Plates at a Gray Medium</ArticleTitle>
<VernacularTitle>The Solution of the Transient Diffusion-Radiation Binary Gas mixture Problem in Low Pressure Values between Two Flat Plates at a Gray Medium</VernacularTitle>
			<FirstPage>1687</FirstPage>
			<LastPage>1704</LastPage>
			<ELocationID EIdType="pii">3195</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14525.5875</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Sohila</FirstName>
					<LastName>Mohammadpour</LastName>
<Affiliation>department of mechanical engineering, University of Sistan and Baluchestan, Zahedan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Samira</FirstName>
					<LastName>Payan</LastName>
<Affiliation>Department of mechanical engineering, University of Sistan and Baluchestan, Zahedan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>05</Month>
					<Day>30</Day>
				</PubDate>
			</History>
		    <Abstract>In this research, a transient two-component radiation-penetration problem is solved numerically. This study aims at investigating the effect of the radiated absorbing gas density in low pressure values on the distribution of the medium temperature in terms of the time, position, and the amount of heat transferred from the radiation environment in terms of the time in two modes of radiation equilibrium and constant temperature of the medium. The modified discrete ordinates method was used to solve the radiation problem; while, the implicit finite volume method was used to solve the transient time penetration problem. The results were observed that the time effect of density led to the time effects on the ambient temperature distribution with a radiated balance and the effects cannot be neglected in states with 1 and 10 mass absorption coefficients. The problem analysis shows that although the radiation equation can be solved in a steady manner for the time interval of interest, one cannot neglect its time effects due to changes in the density of adsorbing gas even at low pressures. By analyzing the problem, it was determined that the temperature effect on density during the radiation equilibrium is rather than the penetration coefficient. This effect is not negligible in 1 and 10 mass absorbing coefficients; therefore this subject emphasizes the importance of considering the penetration coefficient in terms of temperature</Abstract>
			<OtherAbstract Language="FA">In this research, a transient two-component radiation-penetration problem is solved numerically. This study aims at investigating the effect of the radiated absorbing gas density in low pressure values on the distribution of the medium temperature in terms of the time, position, and the amount of heat transferred from the radiation environment in terms of the time in two modes of radiation equilibrium and constant temperature of the medium. The modified discrete ordinates method was used to solve the radiation problem; while, the implicit finite volume method was used to solve the transient time penetration problem. The results were observed that the time effect of density led to the time effects on the ambient temperature distribution with a radiated balance and the effects cannot be neglected in states with 1 and 10 mass absorption coefficients. The problem analysis shows that although the radiation equation can be solved in a steady manner for the time interval of interest, one cannot neglect its time effects due to changes in the density of adsorbing gas even at low pressures. By analyzing the problem, it was determined that the temperature effect on density during the radiation equilibrium is rather than the penetration coefficient. This effect is not negligible in 1 and 10 mass absorbing coefficients; therefore this subject emphasizes the importance of considering the penetration coefficient in terms of temperature</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Transient Radiation-two-component diffusion</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">radiation equilibrium</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Discrete ordinates method</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">gray medium</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Temperature-varying	penetration coefficient</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3195_7f01c939761597f9b832694d4c381512.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
