<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Effect of Start of Injection Timing on Waste Heat Recovery Capacity in a Reactivity Controlled Compression Ignition Engine</ArticleTitle>
<VernacularTitle>Effect of Start of Injection Timing on Waste Heat Recovery Capacity in a Reactivity Controlled Compression Ignition Engine</VernacularTitle>
			<FirstPage>3</FirstPage>
			<LastPage>16</LastPage>
			<ELocationID EIdType="pii">3415</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15465.6128</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mehrdad</FirstName>
					<LastName>Nazemian</LastName>
<Affiliation>Department of Mechanical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Elahe</FirstName>
					<LastName>Neshat</LastName>
<Affiliation>Department of Mechanical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Rahim</FirstName>
					<LastName>Khoshbakhti Saray</LastName>
<Affiliation>Department of Mechanical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		<Abstract>It is noteworthy that about one-third of the input energy to the cylinder of an internal combustion engine becomes useful work and the rest of the energy is lost by various factors. Therefore, providing solutions that can recover waste heat is remarkable and useful. In the current study, the effect of the start of injection timing on the reactivity controlled compression ignition engine on the waste heat recovery capacity has been investigated. After verifying the results, diesel fuel start of injection timing has been changed and their effects on exergy destruction, waste heat recovery capacity, power output and emissions have been investigated. The results showed that the advanced start of injection timing increases engine efficiency and decreases carbon monoxide and unburned hydrocarbons emissions. In addition, heat transfer exergy has increased due to the higher in cylinder temperature, and the higher temperature has led to an increase in irreversibility due to the increased number of reactions. Advanced fuel injection timing has improved utilization.</Abstract>
			<OtherAbstract Language="FA">It is noteworthy that about one-third of the input energy to the cylinder of an internal combustion engine becomes useful work and the rest of the energy is lost by various factors. Therefore, providing solutions that can recover waste heat is remarkable and useful. In the current study, the effect of the start of injection timing on the reactivity controlled compression ignition engine on the waste heat recovery capacity has been investigated. After verifying the results, diesel fuel start of injection timing has been changed and their effects on exergy destruction, waste heat recovery capacity, power output and emissions have been investigated. The results showed that the advanced start of injection timing increases engine efficiency and decreases carbon monoxide and unburned hydrocarbons emissions. In addition, heat transfer exergy has increased due to the higher in cylinder temperature, and the higher temperature has led to an increase in irreversibility due to the increased number of reactions. Advanced fuel injection timing has improved utilization.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Reactivity controlled engine</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Compression ignition engine</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Waste heat recovery</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Injection timing</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Utilization factor</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3415_f6d9e459b9fbf6dd26c4f7d621adec1d.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Investigation of Performance and Emission Characteristic of a Reactivity Controlled Compression Ignition Engine Fueled By a Mixture of Diesel and Syngas Derived From Biomass Gasification</ArticleTitle>
<VernacularTitle>Investigation of Performance and Emission Characteristic of a Reactivity Controlled Compression Ignition Engine Fueled By a Mixture of Diesel and Syngas Derived From Biomass Gasification</VernacularTitle>
			<FirstPage>17</FirstPage>
			<LastPage>30</LastPage>
			<ELocationID EIdType="pii">3618</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15909.6228</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Navid</FirstName>
					<LastName>Kousheshi</LastName>
<Affiliation>University of Bonab</Affiliation>

</Author>
<Author>
					<FirstName>Mortaza</FirstName>
					<LastName>Yari</LastName>
<Affiliation>University of Tabriz</Affiliation>

</Author>
<Author>
					<FirstName>Ali</FirstName>
					<LastName>Saberi Mehr</LastName>
<Affiliation>بناب-فنی و مهندسی- مهندسی مکانیک</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>03</Month>
					<Day>04</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Recently, low-temperature combustion methods have become very popular in &lt;/strong&gt;&lt;strong&gt;the&lt;/strong&gt;&lt;strong&gt; field of combustion. Reactivity controlled compression ignition is a novel combustion concept with its own advantages. The role of these engines in rectifying the disadvantages of other methods is inevitable. This paper studies the influence of using various types of syngas on combustion and emission characteristics of syngas/diesel reactivity controlled compression ignition engine using Converge CFD. Four types of syngas (ideal syngas composed of solely hydrogen and carbon monoxide, two different types of syngases produced by gasifiers and pure hydrogen) are selected for comparison. Results showed the possibility of using various forms of syngases as low reactivity fuel. Using these &lt;/strong&gt;&lt;strong&gt;kinds&lt;/strong&gt;&lt;strong&gt; of syngases compared with ideal one results in fewer nitrogen oxides at the expense of more soot and it gets worse by increasing the fraction of syngas in premixed air. It shouldn’t be ignored, due to the presence of nitrogen in some types, the engine may suffer from weak combustion and sometimes misfire at low loads as well. Using pure hydrogen, despite its advantages as the main part of syngas, in high quantities, notwithstanding the significant reduction of soot, causes the increase of nitrogen oxides and pressure rise rate amounts which are not desirable&lt;/strong&gt;.</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;Recently, low-temperature combustion methods have become very popular in &lt;/strong&gt;&lt;strong&gt;the&lt;/strong&gt;&lt;strong&gt; field of combustion. Reactivity controlled compression ignition is a novel combustion concept with its own advantages. The role of these engines in rectifying the disadvantages of other methods is inevitable. This paper studies the influence of using various types of syngas on combustion and emission characteristics of syngas/diesel reactivity controlled compression ignition engine using Converge CFD. Four types of syngas (ideal syngas composed of solely hydrogen and carbon monoxide, two different types of syngases produced by gasifiers and pure hydrogen) are selected for comparison. Results showed the possibility of using various forms of syngases as low reactivity fuel. Using these &lt;/strong&gt;&lt;strong&gt;kinds&lt;/strong&gt;&lt;strong&gt; of syngases compared with ideal one results in fewer nitrogen oxides at the expense of more soot and it gets worse by increasing the fraction of syngas in premixed air. It shouldn’t be ignored, due to the presence of nitrogen in some types, the engine may suffer from weak combustion and sometimes misfire at low loads as well. Using pure hydrogen, despite its advantages as the main part of syngas, in high quantities, notwithstanding the significant reduction of soot, causes the increase of nitrogen oxides and pressure rise rate amounts which are not desirable&lt;/strong&gt;.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Reactivity controlled compression ignition engine</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Low Temperature Combustion</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Pollution</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Syngas</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3618_4da9d7b6d119db4d2d564a2197798380.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental Study of Injecting Water Vapor and Oil Compounds by Nebulizer on the Efficiency and Natural Gas Flame Pollution</ArticleTitle>
<VernacularTitle>Experimental Study of Injecting Water Vapor and Oil Compounds by Nebulizer on the Efficiency and Natural Gas Flame Pollution</VernacularTitle>
			<FirstPage>31</FirstPage>
			<LastPage>40</LastPage>
			<ELocationID EIdType="pii">3584</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16049.6262</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Amin</FirstName>
					<LastName>Jodat</LastName>
<Affiliation>Mechanical Engineering Department, University of Bojnord, Bojnord 945 3155111, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Mojtaba</FirstName>
					<LastName>Najafian</LastName>
<Affiliation>Mechanical Engineering, Applied Science University of North Khorasan, Bojnord,  Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Abolfazl</FirstName>
					<LastName>Mohammadi</LastName>
<Affiliation>Chemical Engineering Department, University of Bojnord, Bojnord 945 3155111, Iran.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>03</Month>
					<Day>27</Day>
				</PubDate>
			</History>
		<Abstract>In this study, by using nebulizer technology commonly used for the delivery of aerosolized drugs in pulmonary patients, the effect of injecting oil compounds and water vapor by nebulizer on the thermal efficiency and production of pollutants in gas emissions of natural gas diffusion flame is studied. The Nebulizer device creates micron incisions of injected liquid and, due to the reduced injection particle diameter, existing highly turbulent outflow and proper mixing of oil and water vapor compounds with gas and air inlet to the burner, effectiveness of the injection increases to enhance efficiency and reduce pollutants. In the experimental setup, the injection of 1 wt% of oil compounds into the natural gas flame by a nebulizer improves thermal efficiency by 2.5%, decreases the temperature of the exhaust gases from the chimney by 12%, and also pollutants by 13%, and increases carbon monoxide pollutant by 6%. Also, the injection of 2 wt.% of water drops as well as 1 wt.% of oil compounds will increase thermal efficiency by more than 1%, reduce the temperature of chimney exhaust gases by 6 %, reduce pollutants by more than 42 % and carbon monoxide pollutant by 26%.</Abstract>
			<OtherAbstract Language="FA">In this study, by using nebulizer technology commonly used for the delivery of aerosolized drugs in pulmonary patients, the effect of injecting oil compounds and water vapor by nebulizer on the thermal efficiency and production of pollutants in gas emissions of natural gas diffusion flame is studied. The Nebulizer device creates micron incisions of injected liquid and, due to the reduced injection particle diameter, existing highly turbulent outflow and proper mixing of oil and water vapor compounds with gas and air inlet to the burner, effectiveness of the injection increases to enhance efficiency and reduce pollutants. In the experimental setup, the injection of 1 wt% of oil compounds into the natural gas flame by a nebulizer improves thermal efficiency by 2.5%, decreases the temperature of the exhaust gases from the chimney by 12%, and also pollutants by 13%, and increases carbon monoxide pollutant by 6%. Also, the injection of 2 wt.% of water drops as well as 1 wt.% of oil compounds will increase thermal efficiency by more than 1%, reduce the temperature of chimney exhaust gases by 6 %, reduce pollutants by more than 42 % and carbon monoxide pollutant by 26%.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Experimental system</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Natural gas flame</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">nebulizer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal and radiation efficiency</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Pollutants</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3584_565767eb96d87d0d3af8dfb332c2003f.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental Investigation of Combustion Species Radiation to Evaluate Equivalence Ratio in a Surface Flame Burner</ArticleTitle>
<VernacularTitle>Experimental Investigation of Combustion Species Radiation to Evaluate Equivalence Ratio in a Surface Flame Burner</VernacularTitle>
			<FirstPage>41</FirstPage>
			<LastPage>52</LastPage>
			<ELocationID EIdType="pii">3629</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16162.6290</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Hossein</FirstName>
					<LastName>Soltanian</LastName>
<Affiliation>Department of mechanical engineering, Tarbiat Modares University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad</FirstName>
					<LastName>Zabetian Toroghi</LastName>
<Affiliation>تربیت مدرس-مهندسی مکانیک</Affiliation>

</Author>
<Author>
					<FirstName>Hadi</FirstName>
					<LastName>Pasdarshahri</LastName>
<Affiliation>Department of mechanical engineering, Tabiat Modares University, Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>04</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		<Abstract>In the present research, combustion species were investigated in perforated natural gas burner based on flame emission spectroscopy. An experimental investigation is performed on a new burner test rig which is one of the most popular burners used in condensation boilers through a spectrometer-fiber optic to get the flame emission of a perforated burner. Combustion species H&lt;sub&gt;2&lt;/sub&gt;O*, OH*, CH*, C&lt;sub&gt;2&lt;/sub&gt;* and CO&lt;sub&gt;2&lt;/sub&gt;* are detected from their chemiluminescence The emission of CO&lt;sub&gt;2&lt;/sub&gt;* which has the main role in heat release rate of burner was investigated for different equivalence ratios (&lt;em&gt;Φ&lt;/em&gt;) and burner powers of 11-16 kW showing an intensity peak in the range of &lt;em&gt;Φ&lt;/em&gt; between 0.78 to 0.85 that corresponds to the maximum heat release rate. Emission of OH* was also investigated being the main indicator of NO regarding its producing mechanism. Its maximum was found at the range of at &lt;em&gt;Φ&lt;/em&gt;=0.78 to 0.85 for different burner powers. A similar experiment showed that OH*/CH* intensity ratio was independent of burner power as is confirmed by previous researchers. One could infer the equivalence ratio from the flame emission. &lt;br /&gt; </Abstract>
			<OtherAbstract Language="FA">In the present research, combustion species were investigated in perforated natural gas burner based on flame emission spectroscopy. An experimental investigation is performed on a new burner test rig which is one of the most popular burners used in condensation boilers through a spectrometer-fiber optic to get the flame emission of a perforated burner. Combustion species H&lt;sub&gt;2&lt;/sub&gt;O*, OH*, CH*, C&lt;sub&gt;2&lt;/sub&gt;* and CO&lt;sub&gt;2&lt;/sub&gt;* are detected from their chemiluminescence The emission of CO&lt;sub&gt;2&lt;/sub&gt;* which has the main role in heat release rate of burner was investigated for different equivalence ratios (&lt;em&gt;Φ&lt;/em&gt;) and burner powers of 11-16 kW showing an intensity peak in the range of &lt;em&gt;Φ&lt;/em&gt; between 0.78 to 0.85 that corresponds to the maximum heat release rate. Emission of OH* was also investigated being the main indicator of NO regarding its producing mechanism. Its maximum was found at the range of at &lt;em&gt;Φ&lt;/em&gt;=0.78 to 0.85 for different burner powers. A similar experiment showed that OH*/CH* intensity ratio was independent of burner power as is confirmed by previous researchers. One could infer the equivalence ratio from the flame emission. &lt;br /&gt; </OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Species</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Chemiluminescence</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Flat Flame Burner</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3629_1305f6c705349316360c3ccfe7cfe847.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>One-dimensional Combustion Simulation for Different Hydrogen-enriched Natural Gas Blends</ArticleTitle>
<VernacularTitle>One-dimensional Combustion Simulation for Different Hydrogen-enriched Natural Gas Blends</VernacularTitle>
			<FirstPage>53</FirstPage>
			<LastPage>64</LastPage>
			<ELocationID EIdType="pii">3477</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15240.6071</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Ehsan</FirstName>
					<LastName>Bahmani</LastName>
<Affiliation>Department of Mechanical Engineering, Engineering Faculty, Tarbiat Modares University, Tehran, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-9027-0228</Identifier>

</Author>
<Author>
					<FirstName>Kiumars</FirstName>
					<LastName>Mazaheri</LastName>
<Affiliation>Department of Mechanical Engineering, Engineering Faculty, Tarbiat Modares University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Alireza</FirstName>
					<LastName>Alipour</LastName>
<Affiliation>شهید چمران اهواز-مهندسی- گروه مهندسی مکانیک</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>11</Month>
					<Day>03</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Land-based gas turbines are one of the most practical turbines that use natural gas as the main fuel. Since natural gas is produced with different compositions in the refinery process, it can lead to change widely the combustion characteristics. In order to avoid this undesirable variation on combustion characteristics, different methods are suggested. One of these methods is the injection of Hydrogen into the main fuel (i.e. Natural gas). Hydrogen fuel has some desirable properties such as low activation energy, high reaction rate and high burning velocity which makes hydrogen as a suitable additive for modification of combustion characteristics of hydrocarbon fuels. The main purpose of the present study is studying the effects of Hydrogen addition into the different compositions of natural gas to achieve better combustion characteristics. It is observed that the addition of Hydrogen in a specific volumetric percentage into main fuel causes to modify combustion properties, for instance increasing flammability limits.&lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;Land-based gas turbines are one of the most practical turbines that use natural gas as the main fuel. Since natural gas is produced with different compositions in the refinery process, it can lead to change widely the combustion characteristics. In order to avoid this undesirable variation on combustion characteristics, different methods are suggested. One of these methods is the injection of Hydrogen into the main fuel (i.e. Natural gas). Hydrogen fuel has some desirable properties such as low activation energy, high reaction rate and high burning velocity which makes hydrogen as a suitable additive for modification of combustion characteristics of hydrocarbon fuels. The main purpose of the present study is studying the effects of Hydrogen addition into the different compositions of natural gas to achieve better combustion characteristics. It is observed that the addition of Hydrogen in a specific volumetric percentage into main fuel causes to modify combustion properties, for instance increasing flammability limits.&lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Land-based gas turbines</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">natural gas</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hydrogen injection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">chemical kinetics</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">numerical simulation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3477_6d6968d87c240c699190e2d8c029fa9d.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluation of Combustion Models in a Porous Medium with Different Excess Air Ratios</ArticleTitle>
<VernacularTitle>Evaluation of Combustion Models in a Porous Medium with Different Excess Air Ratios</VernacularTitle>
			<FirstPage>65</FirstPage>
			<LastPage>80</LastPage>
			<ELocationID EIdType="pii">3407</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15713.6187</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Hossein</FirstName>
					<LastName>Ajam</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>Iman</FirstName>
					<LastName>Mohammadi</LastName>
<Affiliation>mechanical engineering ferdowsi university of mashhad</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>28</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt; In this paper, the simultaneous study of the effects of the excess air ratio and the combustion mechanisms on the temperature and distribution of species in the porous medium burners with continuous porosity variation has been investigated. For this purpose, multi-step chemical kinetics have been used and their effects on the temperature profile, mass fraction of the main species and emission of pollutants for different values of the excess air ratio have been investigated. Problem-solving equations include continuity equation, momentum equations, gas, and solid phase energy equations, and the chemical equilibrium equation is solved using the finite volume method and the semi-implicit method for pressure linked equations algorithm is used for the relationship between velocity and pressure. The results showed that for excess air ratio of 1.5, the results of combustion mechanisms have the same accuracy in predicting the temperature profile and mass fraction of the main species, and then, for additional values of the excess air ratio, the results of the combustion mechanisms Show a slight difference. This is while the greatest difference in the results is observed for the stoichiometric condition. Also in stoichiometric conditions, the NO emission rate using the GRI-3.0 combustion mechanism is predicted to be zero, and for the rest of the coefficients of the excess air ratio, its value will be of the order of magnitude 10&lt;sup&gt;-6&lt;/sup&gt;.&lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt; In this paper, the simultaneous study of the effects of the excess air ratio and the combustion mechanisms on the temperature and distribution of species in the porous medium burners with continuous porosity variation has been investigated. For this purpose, multi-step chemical kinetics have been used and their effects on the temperature profile, mass fraction of the main species and emission of pollutants for different values of the excess air ratio have been investigated. Problem-solving equations include continuity equation, momentum equations, gas, and solid phase energy equations, and the chemical equilibrium equation is solved using the finite volume method and the semi-implicit method for pressure linked equations algorithm is used for the relationship between velocity and pressure. The results showed that for excess air ratio of 1.5, the results of combustion mechanisms have the same accuracy in predicting the temperature profile and mass fraction of the main species, and then, for additional values of the excess air ratio, the results of the combustion mechanisms Show a slight difference. This is while the greatest difference in the results is observed for the stoichiometric condition. Also in stoichiometric conditions, the NO emission rate using the GRI-3.0 combustion mechanism is predicted to be zero, and for the rest of the coefficients of the excess air ratio, its value will be of the order of magnitude 10&lt;sup&gt;-6&lt;/sup&gt;.&lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">porous media burner</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Chemical Kinetic</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">porosity variation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Axisymmetric Combustion</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">excess air ratio</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3407_dab49080d80c724aad5ebf158d63df41.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Techno-Economic Feasibility of Energy Supply Systems from Renewable Sources of Solar and Biomass in Rural Areas Located In Cold and Dry Climate</ArticleTitle>
<VernacularTitle>Techno-Economic Feasibility of Energy Supply Systems from Renewable Sources of Solar and Biomass in Rural Areas Located In Cold and Dry Climate</VernacularTitle>
			<FirstPage>81</FirstPage>
			<LastPage>100</LastPage>
			<ELocationID EIdType="pii">3594</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16153.6287</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Maryam Sadat</FirstName>
					<LastName>Alaeipour</LastName>
<Affiliation>Department of  Mechanical Engineering, Imam Khomeini International University</Affiliation>

</Author>
<Author>
					<FirstName>Mostafa</FirstName>
					<LastName>Mafi</LastName>
<Affiliation>Department of Mechanical Engineering / Imam Khomeini International University</Affiliation>

</Author>
<Author>
					<FirstName>Mansour</FirstName>
					<LastName>Khanaki</LastName>
<Affiliation>Imam Khomeini International University</Affiliation>

</Author>
<Author>
					<FirstName>Masood</FirstName>
					<LastName>Ebrahimi</LastName>
<Affiliation>Department of Mechanical Engineering, Kurdistan University</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>04</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;The present work focuses on the feasibility study of locally available renewable energy production systems for mountainous rural areas with cold and dry climates (including solar systems and biomass resulted from manure dung). The studied rural area consists of three cold and impassable villages of Pichebon, Narmelat, and Dinheroud, located in Eastern Alamut of Qazvin. Three scenarios have been presented and related techno-economic analyses have been done. Firstly, all heating needs and electricity demands have been met solely by the photovoltaic system. In the second scenario, heating and electricity needs have been supplied by biogas and combined heat and power system. Moreover, the heat loss of the motor has been used to warm up the digester. In the last survey, the electricity need has been supplied by the photovoltaic system along with covering heating demand through biogas. In this scenario, the required heat to operate digester is provided using the photovoltaic system. The results show that the second scenario that has a positive Net Present Value in each discount rate (5%, 10% and 15%) and Internal Rate of Return is 24.24% 23.26% and 38.6% for Pichebon, Narmelat and Dinehroud villages, respectively, is as practical design and economic option.&lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;The present work focuses on the feasibility study of locally available renewable energy production systems for mountainous rural areas with cold and dry climates (including solar systems and biomass resulted from manure dung). The studied rural area consists of three cold and impassable villages of Pichebon, Narmelat, and Dinheroud, located in Eastern Alamut of Qazvin. Three scenarios have been presented and related techno-economic analyses have been done. Firstly, all heating needs and electricity demands have been met solely by the photovoltaic system. In the second scenario, heating and electricity needs have been supplied by biogas and combined heat and power system. Moreover, the heat loss of the motor has been used to warm up the digester. In the last survey, the electricity need has been supplied by the photovoltaic system along with covering heating demand through biogas. In this scenario, the required heat to operate digester is provided using the photovoltaic system. The results show that the second scenario that has a positive Net Present Value in each discount rate (5%, 10% and 15%) and Internal Rate of Return is 24.24% 23.26% and 38.6% for Pichebon, Narmelat and Dinehroud villages, respectively, is as practical design and economic option.&lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Energy production system</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">mountainous rural areas</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">technical and economic calculations</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Photovoltaic</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Biogas</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3594_dce8af15f064d1accb98887a21029b08.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical and Experimental Modal Analysis of a 400 W Polymer Electrolyte Membrane Fuel Cell</ArticleTitle>
<VernacularTitle>Numerical and Experimental Modal Analysis of a 400 W Polymer Electrolyte Membrane Fuel Cell</VernacularTitle>
			<FirstPage>101</FirstPage>
			<LastPage>116</LastPage>
			<ELocationID EIdType="pii">3538</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15878.6216</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mohammad Mahdi</FirstName>
					<LastName>Mohammadi</LastName>
<Affiliation>Fuel cell Technology Research laboratory, Malek Ashtar University of Technology</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad Mahdi</FirstName>
					<LastName>Barzegari</LastName>
<Affiliation>Fuel cell Technology Research laboratory, Malek Ashtar University of Technology</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>02</Month>
					<Day>25</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;With the increasing utilization of polymer electrolyte membrane fuel cells in cars, ships, and airplanes, the study of vibrational behavior of fuel cells has gained particular importance&lt;/strong&gt;&lt;strong&gt;. &lt;/strong&gt;&lt;strong&gt;In this paper, a modal analysis of 400-Watt 4-cells fuel cell with an active surface area of 225 &lt;/strong&gt;&lt;strong&gt; has been performed numerically and experimentally. The time domain method has been used to extract global fuel cell frequencies. By interpreting the output data of the sensors and using the phase response angle, two natural frequencies of the model were extracted. &lt;/strong&gt;&lt;strong&gt;The results of the test showed that the first transverse and longitudinal frequency of the model is 500 Hz and about 2500 Hz, respectively. Then, the simulation of the finite element model was studied in detail. A comparison of the frequencies obtained from the test and numerical analysis showed that the maximum difference is about 8%&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt; Therefore, numerical analysis of the model with sufficient detail can adequately cover the vibrational properties of the real model&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt; Also, the results showed that by changing the geometrical and mechanical properties of the membrane by 45%, the natural frequency of fuel cell changes through 4%&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt; Furthermore, removing the membrane plates, in addition to reducing the number of model elements, reduces the contact constraints&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;With the increasing utilization of polymer electrolyte membrane fuel cells in cars, ships, and airplanes, the study of vibrational behavior of fuel cells has gained particular importance&lt;/strong&gt;&lt;strong&gt;. &lt;/strong&gt;&lt;strong&gt;In this paper, a modal analysis of 400-Watt 4-cells fuel cell with an active surface area of 225 &lt;/strong&gt;&lt;strong&gt; has been performed numerically and experimentally. The time domain method has been used to extract global fuel cell frequencies. By interpreting the output data of the sensors and using the phase response angle, two natural frequencies of the model were extracted. &lt;/strong&gt;&lt;strong&gt;The results of the test showed that the first transverse and longitudinal frequency of the model is 500 Hz and about 2500 Hz, respectively. Then, the simulation of the finite element model was studied in detail. A comparison of the frequencies obtained from the test and numerical analysis showed that the maximum difference is about 8%&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt; Therefore, numerical analysis of the model with sufficient detail can adequately cover the vibrational properties of the real model&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt; Also, the results showed that by changing the geometrical and mechanical properties of the membrane by 45%, the natural frequency of fuel cell changes through 4%&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt; Furthermore, removing the membrane plates, in addition to reducing the number of model elements, reduces the contact constraints&lt;/strong&gt;&lt;strong&gt;.&lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Polymer electrolyte membrane fuel cells</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">modal analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Natural frequency</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Finite element simulation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3538_1458e7509aa5f47ecfb92536e7dd1dc7.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Simulation and Optimization of Rankine Power Generation Cycle Purposing the Efficiency of Liquefied Natural Gas Cold Exergy</ArticleTitle>
<VernacularTitle>Simulation and Optimization of Rankine Power Generation Cycle Purposing the Efficiency of Liquefied Natural Gas Cold Exergy</VernacularTitle>
			<FirstPage>117</FirstPage>
			<LastPage>134</LastPage>
			<ELocationID EIdType="pii">3400</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15583.6161</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Alireza</FirstName>
					<LastName>Sadeghi</LastName>
<Affiliation>Imam Khomeini international university, Qazvin, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohsen</FirstName>
					<LastName>Kashi Parpinchi</LastName>
<Affiliation>Imam Khomeini international university, Qazvin, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Seyed Abbas</FirstName>
					<LastName>Sadatsakak</LastName>
<Affiliation>Imam Khomeini International University</Affiliation>

</Author>
<Author>
					<FirstName>Mansour</FirstName>
					<LastName>Khanaki</LastName>
<Affiliation>Imam Khomeini International University</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>05</Day>
				</PubDate>
			</History>
		<Abstract>Liquefied natural gas is obtained by cooling the natural gas to −162℃ at the atmospheric pressure. Methane is the major chemical component of liquefied natural gas which varies between 87.0–99.8% for different sources. The cryogenic power generation cycle using liquefied natural gas as its heat sink is known to be one of the considerable ways for the liquefied natural gas exergy recovery. A double-stage Rankine power generation cycle using the single component working fluid in each stage for liquefied natural gas cold exergy recovery is used as a base case in the present study. To improve the recovery of liquefied natural gas cold exergy, a three-stage Rankine power generation cycle has been proposed using mixture working fluid. Optimization is done using the particle swarm algorithm. The performance of the three-stage Rankine power generation cycle is studied regarding the effects of thermal efficiencies, exergy efficiencies, overall heat transfer coefficient of condensers and natural gas distribution pressure. Specific power production of the cycle is 100.45, thermal efficiency is 12.76%, and exergy efficiency is 27.92%. By decreasing the total coefficient of heat transfer, the condensers of different stages of the cycle reduce the maximum output power of the cycle with different trends. The results show that by decreasing the distribution pressure of natural gas, specific power production, thermal efficiency and exergy efficiency increases. So that their optimal values at 6 bar are 290.87, 25.63% and 39.12%, respectively. &lt;br /&gt; </Abstract>
			<OtherAbstract Language="FA">Liquefied natural gas is obtained by cooling the natural gas to −162℃ at the atmospheric pressure. Methane is the major chemical component of liquefied natural gas which varies between 87.0–99.8% for different sources. The cryogenic power generation cycle using liquefied natural gas as its heat sink is known to be one of the considerable ways for the liquefied natural gas exergy recovery. A double-stage Rankine power generation cycle using the single component working fluid in each stage for liquefied natural gas cold exergy recovery is used as a base case in the present study. To improve the recovery of liquefied natural gas cold exergy, a three-stage Rankine power generation cycle has been proposed using mixture working fluid. Optimization is done using the particle swarm algorithm. The performance of the three-stage Rankine power generation cycle is studied regarding the effects of thermal efficiencies, exergy efficiencies, overall heat transfer coefficient of condensers and natural gas distribution pressure. Specific power production of the cycle is 100.45, thermal efficiency is 12.76%, and exergy efficiency is 27.92%. By decreasing the total coefficient of heat transfer, the condensers of different stages of the cycle reduce the maximum output power of the cycle with different trends. The results show that by decreasing the distribution pressure of natural gas, specific power production, thermal efficiency and exergy efficiency increases. So that their optimal values at 6 bar are 290.87, 25.63% and 39.12%, respectively. &lt;br /&gt; </OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Liquefied Natural Gas</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Rankine cycle</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Cold exergy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Regasification</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Power Generation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3400_e945de21a1bb5714a0bc8a897ed32e9f.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Thermodynamic Analysis of a Novel Power, Cooling, Hydrogen and Oxygen Multi-Generation Combined Cycle Based on the Sabalan Geothermal Wells</ArticleTitle>
<VernacularTitle>Thermodynamic Analysis of a Novel Power, Cooling, Hydrogen and Oxygen Multi-Generation Combined Cycle Based on the Sabalan Geothermal Wells</VernacularTitle>
			<FirstPage>135</FirstPage>
			<LastPage>154</LastPage>
			<ELocationID EIdType="pii">3369</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15500.6138</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mehran</FirstName>
					<LastName>Abdolalipouradl</LastName>
<Affiliation>Mechanical Engineering Department, Faculty of engineering, Urmia University, Urmia, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Shahram</FirstName>
					<LastName>Khalilarya</LastName>
<Affiliation></Affiliation>
<Identifier Source="ORCID">0000-0002-6434-852X</Identifier>

</Author>
<Author>
					<FirstName>Farzad</FirstName>
					<LastName>Mohammadkhani</LastName>
<Affiliation>Department of Mechanical Engineering, Mechanical Engineering Faculty, University of Tabriz, Tabriz, Iran</Affiliation>
<Identifier Source="ORCID">0000-0003-3399-3099</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>22</Day>
				</PubDate>
			</History>
		<Abstract>The use of multi-generation systems is rapidly developing in the world. Although Sabalan geothermal field is one of the important geothermal fields of Iran, the possibility of using the multi-generation systems has not yet been performed. As an attempt to fulfill the gap in the field, a new cooling, hydrogen, oxygen, and power multi-generation cycle for using Sabalan geothermal wells is proposed and analyzed. In the proposed system, the double flash configuration from the Sabalan geothermal wells as the heat source is used. An organic Rankine cycle is used to generate power for the proton exchange membrane for hydrogen production and a LiBr-H&lt;sub&gt;2&lt;/sub&gt;O absorption refrigeration system is used for cooling production. First, a simulation was done by Engineering Equation Solver software and then the effects of some design parameters, such as separators pressures, evaporator temperature, pinch point temperature difference in the Rankine evaporator, generator temperature and ambient temperature on the integrated system performance are studied. A parametric study shows that the value of the thermal efficiency and cooling continuously increases with separators&#039; pressures. According to the results, the value of the net output power, hydrogen production, cooling and thermal and exergy efficiencies of the cogeneration system are obtained as 14739 kW, 13.25 kg/hr, 10925 kW, 22.34% and 50.62% respectively.</Abstract>
			<OtherAbstract Language="FA">The use of multi-generation systems is rapidly developing in the world. Although Sabalan geothermal field is one of the important geothermal fields of Iran, the possibility of using the multi-generation systems has not yet been performed. As an attempt to fulfill the gap in the field, a new cooling, hydrogen, oxygen, and power multi-generation cycle for using Sabalan geothermal wells is proposed and analyzed. In the proposed system, the double flash configuration from the Sabalan geothermal wells as the heat source is used. An organic Rankine cycle is used to generate power for the proton exchange membrane for hydrogen production and a LiBr-H&lt;sub&gt;2&lt;/sub&gt;O absorption refrigeration system is used for cooling production. First, a simulation was done by Engineering Equation Solver software and then the effects of some design parameters, such as separators pressures, evaporator temperature, pinch point temperature difference in the Rankine evaporator, generator temperature and ambient temperature on the integrated system performance are studied. A parametric study shows that the value of the thermal efficiency and cooling continuously increases with separators&#039; pressures. According to the results, the value of the net output power, hydrogen production, cooling and thermal and exergy efficiencies of the cogeneration system are obtained as 14739 kW, 13.25 kg/hr, 10925 kW, 22.34% and 50.62% respectively.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Thermodynamic analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sabalan geothermal power plant</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Proton exchange membrane electrolysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Absorption refrigeration</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Organic Rankine cycle</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3369_dda99de58ff020cfb57fec1404c97003.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>The Feasibility Study of a Night Sky Radiative Cooling System for Cooling the Intake Air of a Gas Turbine</ArticleTitle>
<VernacularTitle>The Feasibility Study of a Night Sky Radiative Cooling System for Cooling the Intake Air of a Gas Turbine</VernacularTitle>
			<FirstPage>155</FirstPage>
			<LastPage>172</LastPage>
			<ELocationID EIdType="pii">3492</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15461.6127</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mohammad Reza</FirstName>
					<LastName>Sangtarash</LastName>
<Affiliation>Mechanical engineering department- Engineering faculty- Unversity of Sistan and Balouchestan- Zahedan- Iran</Affiliation>

</Author>
<Author>
					<FirstName>Said</FirstName>
					<LastName>Farahat</LastName>
<Affiliation>Mechanical engineering department- Engineering faculty- Unversity of Sistan and Balouchestan- Zahedan- Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mostafa</FirstName>
					<LastName>Dehghani Mohammadabadi</LastName>
<Affiliation>Mechanical engineering department- Engineering faculty- Unversity of Sistan and Balouchestan- Zahedan- Iran</Affiliation>
<Identifier Source="ORCID">0000-0003-2888-8411</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		<Abstract>The compressor inlet air cooling, especially in hot climates, has a significant effect on the power output augmentation of the gas turbines. The water consumption in evaporative cooling and fogging systems and power consumption and investment cost in vapor absorption and compression refrigeration systems are high. So, the purpose of this article is to investigate the possibility of using the night sky radiative cooling system for cooling the intake air of the compressor. In this method, the circulating water used to cool the intake air of the compressor, at night and in the exchange of radiation with the sky, is cooled using glassless flat plate collectors and returns to the storage tank for reuse on the next day. The effect of parameters such as the number and arrangement of collectors in series or parallel on the cooling capacity is investigated. Also, the required storage tank volume for returned water from collectors is calculated. The results show that the compressor’s intake air cooling for six hours a day needs a storage tank with a minimum capacity of 1000 m&lt;sup&gt;3&lt;/sup&gt;. Also, by using 400 parallel collectors and a 1000 m&lt;sup&gt;3&lt;/sup&gt; storage tank, the power production increases by an average of 2 MWh.</Abstract>
			<OtherAbstract Language="FA">The compressor inlet air cooling, especially in hot climates, has a significant effect on the power output augmentation of the gas turbines. The water consumption in evaporative cooling and fogging systems and power consumption and investment cost in vapor absorption and compression refrigeration systems are high. So, the purpose of this article is to investigate the possibility of using the night sky radiative cooling system for cooling the intake air of the compressor. In this method, the circulating water used to cool the intake air of the compressor, at night and in the exchange of radiation with the sky, is cooled using glassless flat plate collectors and returns to the storage tank for reuse on the next day. The effect of parameters such as the number and arrangement of collectors in series or parallel on the cooling capacity is investigated. Also, the required storage tank volume for returned water from collectors is calculated. The results show that the compressor’s intake air cooling for six hours a day needs a storage tank with a minimum capacity of 1000 m&lt;sup&gt;3&lt;/sup&gt;. Also, by using 400 parallel collectors and a 1000 m&lt;sup&gt;3&lt;/sup&gt; storage tank, the power production increases by an average of 2 MWh.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Gas turbine</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Air Intake cooling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Night Sky Radiative Cooling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Passive Cooling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Solar collector</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3492_0060ef47b12160b9198302ebdb144dcf.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Thermal Analysis of a Solar Wall Equipped with Photovoltaic Cells and Phase-Change Materials</ArticleTitle>
<VernacularTitle>Thermal Analysis of a Solar Wall Equipped with Photovoltaic Cells and Phase-Change Materials</VernacularTitle>
			<FirstPage>173</FirstPage>
			<LastPage>190</LastPage>
			<ELocationID EIdType="pii">3641</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16268.6315</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Nahid</FirstName>
					<LastName>Azadi</LastName>
<Affiliation>Masters student, Department of Mechanical Engineering, Sistan and Baluchestan University, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Faramarz</FirstName>
					<LastName>Sarhaddi</LastName>
<Affiliation>Head of Department of Mechanical Engineering
Research Laboratory of Renewable Energies and Electromagnetic Fluids, Department of Mechanical Engineering, University of Sistan and Baluchestan, Zahedan, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-5216-9823</Identifier>

</Author>
<Author>
					<FirstName>Fatemeh</FirstName>
					<LastName>Sobhnamayan</LastName>
<Affiliation>Department of Mechanical Engineering, University of Sistan and Baluchestan, Zahedan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>05</Month>
					<Day>04</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;In this paper, the thermal analysis of a solar wall system equipped with photovoltaic cells and phase-change materials has been numerically investigated. For the thermal modeling of the system, the energy balance for its various components, including photovoltaic cells, air channel, absorber plate, phase-change material, and room are written. The validation of the numerical results is consistent with the experimental data of previous studies. In parametric studies, the effect of phase-change material thickness, inlet air flow rate, collector width, and packing factor have been investigated on the room temperature and system average energy efficiency in four consecutive days. Results show that the optimal phase-change material thickness is 0.05 m. Increasing the phase-change material thickness reduces the room temperature and energy efficiency. Increasing the airflow rate decreases the photovoltaic cell temperature and increases electrical efficiency, thereby increasing energy efficiency. However, it reduces room temperature. Therefore, the optimum flow rate of air was obtained at 0.04 kg/s. Increasing the collector width, despite increasing room temperature, reduces energy efficiency, so the optimum collector width was 0.7 m. The increase of the packing factor increases room temperature and reduces energy efficiency. Therefore, the optimum packing factor was 0.5.&lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;In this paper, the thermal analysis of a solar wall system equipped with photovoltaic cells and phase-change materials has been numerically investigated. For the thermal modeling of the system, the energy balance for its various components, including photovoltaic cells, air channel, absorber plate, phase-change material, and room are written. The validation of the numerical results is consistent with the experimental data of previous studies. In parametric studies, the effect of phase-change material thickness, inlet air flow rate, collector width, and packing factor have been investigated on the room temperature and system average energy efficiency in four consecutive days. Results show that the optimal phase-change material thickness is 0.05 m. Increasing the phase-change material thickness reduces the room temperature and energy efficiency. Increasing the airflow rate decreases the photovoltaic cell temperature and increases electrical efficiency, thereby increasing energy efficiency. However, it reduces room temperature. Therefore, the optimum flow rate of air was obtained at 0.04 kg/s. Increasing the collector width, despite increasing room temperature, reduces energy efficiency, so the optimum collector width was 0.7 m. The increase of the packing factor increases room temperature and reduces energy efficiency. Therefore, the optimum packing factor was 0.5.&lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Solar wall</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Phase-change materials</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Photovoltaic cell</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal analysis</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3641_22c5a901070d1c2ad33e821d071ae97e.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Effect of Air Curtain on Occupants Thermal Comfort and Indoor Air Quality in an Athletic Swimming Pool with Spectators’ Stand</ArticleTitle>
<VernacularTitle>Effect of Air Curtain on Occupants Thermal Comfort and Indoor Air Quality in an Athletic Swimming Pool with Spectators’ Stand</VernacularTitle>
			<FirstPage>191</FirstPage>
			<LastPage>208</LastPage>
			<ELocationID EIdType="pii">3193</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2018.14584.5892</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Alireza</FirstName>
					<LastName>Zolfaghari</LastName>
<Affiliation>University of Birjand</Affiliation>
<Identifier Source="ORCID">0000-0001-9917-3400</Identifier>

</Author>
<Author>
					<FirstName>Saeed</FirstName>
					<LastName>Azizi</LastName>
<Affiliation>University of Birjand</Affiliation>

</Author>
<Author>
					<FirstName>Seyed Mohammad</FirstName>
					<LastName>Hooshmand</LastName>
<Affiliation>University of Birjand</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;In swimming pools with spectators’ stand, due to differences in skin wetness, metabolic rates and clothing type of the swimmers and spectators, providing thermal comfort conditions for all residents is very difficult. Accordingly, using the air curtain to aerodynamically separate the pool hall and the spectators’ stand is a reasonable idea to provide the mentioned different thermal comfort conditions. In the mentioned conditions, it is possible to use two different ventilation systems for these two parts. In the present study, an Olympic-size swimming pool with the spectators’ stand is modeled and distribution of velocity, temperature, relative humidity, and chlorine concentration have been determined. Also, the results have been analyzed in both cases: using air curtain and without air curtain. The results show that the air curtain can significantly reduce the influence of chlorine pollutants on the spectators&#039; section, so the concentration of chlorine at spectators’ stand with the air curtain is about 0.00016 mg/m&lt;sup&gt;3&lt;/sup&gt; less than the case without air curtain. In this study, 65 multi node local thermal comfort model has been used to determine the thermal comfort of individuals. In the case of using the air curtain, the standard deviation of thermal comfort index for first to third rows are 0.26, 0.25, and 0.28 respectively; and in the absence of air curtain, for first to third rows the standard deviation of thermal comfort index are 0.33, 0.39 and 0.35, respectively. These results indicate that using the air curtain can lead the thermal sensation to be more favorable and more uniform.&lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;In swimming pools with spectators’ stand, due to differences in skin wetness, metabolic rates and clothing type of the swimmers and spectators, providing thermal comfort conditions for all residents is very difficult. Accordingly, using the air curtain to aerodynamically separate the pool hall and the spectators’ stand is a reasonable idea to provide the mentioned different thermal comfort conditions. In the mentioned conditions, it is possible to use two different ventilation systems for these two parts. In the present study, an Olympic-size swimming pool with the spectators’ stand is modeled and distribution of velocity, temperature, relative humidity, and chlorine concentration have been determined. Also, the results have been analyzed in both cases: using air curtain and without air curtain. The results show that the air curtain can significantly reduce the influence of chlorine pollutants on the spectators&#039; section, so the concentration of chlorine at spectators’ stand with the air curtain is about 0.00016 mg/m&lt;sup&gt;3&lt;/sup&gt; less than the case without air curtain. In this study, 65 multi node local thermal comfort model has been used to determine the thermal comfort of individuals. In the case of using the air curtain, the standard deviation of thermal comfort index for first to third rows are 0.26, 0.25, and 0.28 respectively; and in the absence of air curtain, for first to third rows the standard deviation of thermal comfort index are 0.33, 0.39 and 0.35, respectively. These results indicate that using the air curtain can lead the thermal sensation to be more favorable and more uniform.&lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Swimming pool</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Air curtain</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal comfort</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Local sensation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Indoor air quality</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3193_68a9750337a418a86fe06c1991a1d64c.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>An Experimental Investigation on the Convective Heat Transfer Coefficient and Nusselt Number in Water/Carbon Nanofluid</ArticleTitle>
<VernacularTitle>An Experimental Investigation on the Convective Heat Transfer Coefficient and Nusselt Number in Water/Carbon Nanofluid</VernacularTitle>
			<FirstPage>209</FirstPage>
			<LastPage>220</LastPage>
			<ELocationID EIdType="pii">3642</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16148.6289</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Amir Hossein</FirstName>
					<LastName>Shiravi</LastName>
<Affiliation>Department of Mechanical Engineering, Faculty of Mechanical engineering, Jundi-Shapur University of technology, Dezful, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mojtaba</FirstName>
					<LastName>Shafiee</LastName>
<Affiliation>Department of Chemical Engineering, Faculty of Chemical Engineering, Jundi-Shapur University of Technology, Dezful, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Hadis</FirstName>
					<LastName>Bostani</LastName>
<Affiliation>Department of Mechanical Engineering, Jundi-Shapur University of Technology, Dezful, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad</FirstName>
					<LastName>Firoozzadeh</LastName>
<Affiliation>Department of Mechanical Engineering, Faculty of Mechanical Engineering, Jundi-Shapur University of technology, Dezful, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Maryam</FirstName>
					<LastName>Bozorgmehrian</LastName>
<Affiliation>Department of Mechanical Engineering, Mechanical faculty, Jundi-Shapur University of Technology, Dezful, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>04</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		<Abstract>The heat transfer coefficient of fluid is one of the most important effective factors on the performance of fluid in the heat transfer process. Due to the higher conductive heat transfer coefficient of metals than liquids, metal particles can be used to increase the heat transfer rate of liquids. Nanofluid is one of the novels and developing methods to improve the heat transfer rate in heat exchangers. In this paper, the main effective parameters (flow rate and concentration) on increasing the convective heat transfer coefficient of water carbon nanofluid compared with water as a base fluid, are investigated in the Reynolds range of 7,100 to 16,700. The results illustrate that increasing the &lt;em&gt;Re&lt;/em&gt; leads to increase in the Nusselt number and convective heat transfer coefficient, and also to decrease the friction factor. It is also shown that at a constant &lt;em&gt;Re&lt;/em&gt;, carbon nanofluid is able to enhance the convective heat transfer coefficient up to 10.17%, compared with pure water. It is found that adding carbon nanoparticles to water, initially leads to increasing the convective heat transfer coefficient, while this trend continues until the concentration of about 0.2 wt%, and then has a descending trend. In addition, the pressure drop was investigated due to changes in Re and was shown that the behavior of this curve is in agreement with Moody’s diagram.</Abstract>
			<OtherAbstract Language="FA">The heat transfer coefficient of fluid is one of the most important effective factors on the performance of fluid in the heat transfer process. Due to the higher conductive heat transfer coefficient of metals than liquids, metal particles can be used to increase the heat transfer rate of liquids. Nanofluid is one of the novels and developing methods to improve the heat transfer rate in heat exchangers. In this paper, the main effective parameters (flow rate and concentration) on increasing the convective heat transfer coefficient of water carbon nanofluid compared with water as a base fluid, are investigated in the Reynolds range of 7,100 to 16,700. The results illustrate that increasing the &lt;em&gt;Re&lt;/em&gt; leads to increase in the Nusselt number and convective heat transfer coefficient, and also to decrease the friction factor. It is also shown that at a constant &lt;em&gt;Re&lt;/em&gt;, carbon nanofluid is able to enhance the convective heat transfer coefficient up to 10.17%, compared with pure water. It is found that adding carbon nanoparticles to water, initially leads to increasing the convective heat transfer coefficient, while this trend continues until the concentration of about 0.2 wt%, and then has a descending trend. In addition, the pressure drop was investigated due to changes in Re and was shown that the behavior of this curve is in agreement with Moody’s diagram.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Nanofluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heat transfer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Nusselt number</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Friction factor</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3642_300d1539c3b6aa1793b5678b857732cf.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical Simulation of Heat Transfer Turbulent Flow for Non-Newtonian Nanofluid in a Double Pipe Helical Heat Exchanger</ArticleTitle>
<VernacularTitle>Numerical Simulation of Heat Transfer Turbulent Flow for Non-Newtonian Nanofluid in a Double Pipe Helical Heat Exchanger</VernacularTitle>
			<FirstPage>221</FirstPage>
			<LastPage>240</LastPage>
			<ELocationID EIdType="pii">3488</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16033.6256</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Kourosh</FirstName>
					<LastName>Javaherdeh</LastName>
<Affiliation>Instructor of Department of Mechanical Engineering, Faculty of Engineering, University of Guilan</Affiliation>
<Identifier Source="ORCID">0000-0002-1570-011X</Identifier>

</Author>
<Author>
					<FirstName>Seyed Shahab</FirstName>
					<LastName>Mozafarie</LastName>
<Affiliation>Faculty of Mechanical Engineering, University of Guilan, Rash, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Zeinab</FirstName>
					<LastName>Zare Talab</LastName>
<Affiliation>Faculty of Mechanical Engineering, University of Guilan, Rasht, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>03</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		<Abstract>In this research, the thermal and hydrodynamic behavior of a non-Newtonian nanofluid turbulent flow in the counterflow arrangement in a double pipe helical heat exchanger is numerically simulated. A solution of carboxymethyl cellulose powder in water with a mass percentage of 0.1% with a nanoparticle of aluminum oxide as a working fluid has been used. The computational fluid dynamics commercial software Fluent was used to solve the governing equations, the results were in a good agreement with experimental data. The effect of important parameters such as curvature, Reynolds number and volume percentage of aluminum oxide nanoparticles on the heat transfer has been investigated. The results show that as the curvature ratio increases in constant Dean (&lt;em&gt;Dn&lt;/em&gt;) numbers, the &lt;em&gt;Nu&lt;/em&gt; number and the coefficient of friction increase. The addition of nanoparticles of aluminum oxide to the base fluid for the flow with the constant Reynolds and &lt;em&gt;Dn&lt;/em&gt; number increases the heat transfer and increases the pressure drop in the helically coiled tubes. The centrifugal force generated by the curvature of the coiled tubes results in a secondary flow in the heat exchanger so that the heat transfer and pressure drop increased up to 35% and 30%, respectively, compared to the straight tubes. The effect of heat transfer enhancement methods on the hydrodynamic index has also been studied, so that in the helical coils, the amount of hydrodynamic index increased with decreasing curvature ratio and increasing the volume concentration of nanoparticles.</Abstract>
			<OtherAbstract Language="FA">In this research, the thermal and hydrodynamic behavior of a non-Newtonian nanofluid turbulent flow in the counterflow arrangement in a double pipe helical heat exchanger is numerically simulated. A solution of carboxymethyl cellulose powder in water with a mass percentage of 0.1% with a nanoparticle of aluminum oxide as a working fluid has been used. The computational fluid dynamics commercial software Fluent was used to solve the governing equations, the results were in a good agreement with experimental data. The effect of important parameters such as curvature, Reynolds number and volume percentage of aluminum oxide nanoparticles on the heat transfer has been investigated. The results show that as the curvature ratio increases in constant Dean (&lt;em&gt;Dn&lt;/em&gt;) numbers, the &lt;em&gt;Nu&lt;/em&gt; number and the coefficient of friction increase. The addition of nanoparticles of aluminum oxide to the base fluid for the flow with the constant Reynolds and &lt;em&gt;Dn&lt;/em&gt; number increases the heat transfer and increases the pressure drop in the helically coiled tubes. The centrifugal force generated by the curvature of the coiled tubes results in a secondary flow in the heat exchanger so that the heat transfer and pressure drop increased up to 35% and 30%, respectively, compared to the straight tubes. The effect of heat transfer enhancement methods on the hydrodynamic index has also been studied, so that in the helical coils, the amount of hydrodynamic index increased with decreasing curvature ratio and increasing the volume concentration of nanoparticles.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Double pipe helical heat exchanger</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">numerical simulation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heat transfer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Nanofluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Turbulent flow</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3488_c7b90b0fc23725f299b47c5224e6ec0d.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Investigation of Heat Transfer of Non-Newtonian Pseudo-Plastic Fluids in Porous Heat Exchangers</ArticleTitle>
<VernacularTitle>Investigation of Heat Transfer of Non-Newtonian Pseudo-Plastic Fluids in Porous Heat Exchangers</VernacularTitle>
			<FirstPage>241</FirstPage>
			<LastPage>258</LastPage>
			<ELocationID EIdType="pii">3448</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15536.6153</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Amin Reza</FirstName>
					<LastName>Noghreabadi</LastName>
<Affiliation>Mechanical Engineering Department, Faculty of Engineering, Shahid Chamran of Ahvaz University, Ahvaz, IRAN</Affiliation>

</Author>
<Author>
					<FirstName>Kasra</FirstName>
					<LastName>Ayoubi Ayoubloo</LastName>
<Affiliation>Mechanical Engineering Department, Faculty of Engineering, Shahid Chamran of Ahvaz University, Ahvaz, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Reza</FirstName>
					<LastName>Bahoosh Kazerooni</LastName>
<Affiliation>Mechanical Engineering Department, Faculty of Engineering, Shahid Chamran of Ahvaz University, Ahvaz, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad</FirstName>
					<LastName>Ghalambaz</LastName>
<Affiliation>Assistant professor, Department of Mechanical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran</Affiliation>
<Identifier Source="ORCID">0000-0003-0965-2358</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>12</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;In this paper, the natural heat transfer of Rayleigh-Benard&#039;s non-Newtonian Pseudo-Plastics fluid in a tube heat exchanger with its left wall lined with a porous layer of a thickness &lt;em&gt;l&lt;/em&gt; is considered numerically for an unstable state of laminar. The lower wall of the heat exchanger is at constant temperature &lt;em&gt;T&lt;sub&gt;h&lt;/sub&gt;&lt;/em&gt;and the upper wall at &lt;em&gt;T&lt;sub&gt;c&lt;/sub&gt; &lt;/em&gt;temperature (&lt;em&gt;T&lt;sub&gt;h&lt;/sub&gt;&gt;T&lt;sub&gt;c&lt;/sub&gt;&lt;/em&gt;). The walls are left and right insulated. The dimensionless governing equations are solved by the finite element method and the accuracy of the results is compared with previous studies. The results show that, in a large Rayleigh number, the average Nusselt number increases due to the fact that the natural heat transfer is more than conduction heat transfer. Also, in small Darcy numbers, the flow permeability is very low which causes reduce natural heat transfer convection. The results show that by decreasing the Power-law index, the non-dimensional temperature is reduced and the lowest non-dimensional temperature is obtained for the lowest Power-law index. On the other hand, with the increase of the Power-law index in a constant Rayleigh number and the passage of time, the increase of natural heat transfer occurs in the tube. Also, the Rayleigh number decreases with the increase of the Power-law index to start the natural convection in the heat exchanger.&lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;In this paper, the natural heat transfer of Rayleigh-Benard&#039;s non-Newtonian Pseudo-Plastics fluid in a tube heat exchanger with its left wall lined with a porous layer of a thickness &lt;em&gt;l&lt;/em&gt; is considered numerically for an unstable state of laminar. The lower wall of the heat exchanger is at constant temperature &lt;em&gt;T&lt;sub&gt;h&lt;/sub&gt;&lt;/em&gt;and the upper wall at &lt;em&gt;T&lt;sub&gt;c&lt;/sub&gt; &lt;/em&gt;temperature (&lt;em&gt;T&lt;sub&gt;h&lt;/sub&gt;&gt;T&lt;sub&gt;c&lt;/sub&gt;&lt;/em&gt;). The walls are left and right insulated. The dimensionless governing equations are solved by the finite element method and the accuracy of the results is compared with previous studies. The results show that, in a large Rayleigh number, the average Nusselt number increases due to the fact that the natural heat transfer is more than conduction heat transfer. Also, in small Darcy numbers, the flow permeability is very low which causes reduce natural heat transfer convection. The results show that by decreasing the Power-law index, the non-dimensional temperature is reduced and the lowest non-dimensional temperature is obtained for the lowest Power-law index. On the other hand, with the increase of the Power-law index in a constant Rayleigh number and the passage of time, the increase of natural heat transfer occurs in the tube. Also, the Rayleigh number decreases with the increase of the Power-law index to start the natural convection in the heat exchanger.&lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Rayleigh-Benard convection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Non-Newtonian fluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">pseudo-plastic</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heat exchanger</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Porous Layer</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3448_c5bbd980e5ab2c17413ec02bd757a9e5.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Effects of Magnetic Field on Natural Convection of Non-Newtonian Fluid in a Square Enclosure with a Central Heat Source</ArticleTitle>
<VernacularTitle>Effects of Magnetic Field on Natural Convection of Non-Newtonian Fluid in a Square Enclosure with a Central Heat Source</VernacularTitle>
			<FirstPage>259</FirstPage>
			<LastPage>278</LastPage>
			<ELocationID EIdType="pii">3513</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16101.6274</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Akram</FirstName>
					<LastName>Jahanbakhshi</LastName>
<Affiliation>Shahrekord University, Shahrekord</Affiliation>

</Author>
<Author>
					<FirstName>Afshin</FirstName>
					<LastName>Ahmadi Nadooshan</LastName>
<Affiliation>Mechanical Engineering Department, Shahrekord University, Shahrekord</Affiliation>
<Identifier Source="ORCID">0000-0003-4345-9527</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>04</Month>
					<Day>09</Day>
				</PubDate>
			</History>
		<Abstract>In this study, the incompressible laminar flow of non-Newtonian fluid is studied in a cavity with a central heat source under a uniform inclined magnetic field. The governing equations are converted into nonlinear ordinary differential equations using similarity transformations and solved using finite difference based numerical methods. In the current study, the effect of non-Newtonian power-law fluid is investigated for power-law indices of 0.75, 1 and 1.4. The results are compared with the ones in which the magnetic field is not applied. It is found that the implementation of a magnetic field for different fluid indices in different Rayleigh numbers does not show similar behaviors and the results show that the magnetic field affects the convection flow, leading to a reduction in it. Also can be said that with the implementation of a magnetic field in the range of indices &lt;em&gt;n&lt;/em&gt; ≥ 1 for power-law model fluid, increased Rayleigh number leads to reduced average Nusselt number and for &lt;em&gt;n&lt;/em&gt; ˂ 1, the average Nusselt increases. For &lt;em&gt;n&lt;/em&gt; ˂ 1, with increased Rayleigh number in the presence of a fixed magnetic field, free convection can be weakened while this trend for &lt;em&gt;n&lt;/em&gt; ˂ 1 occurs with reduced Rayleigh number.</Abstract>
			<OtherAbstract Language="FA">In this study, the incompressible laminar flow of non-Newtonian fluid is studied in a cavity with a central heat source under a uniform inclined magnetic field. The governing equations are converted into nonlinear ordinary differential equations using similarity transformations and solved using finite difference based numerical methods. In the current study, the effect of non-Newtonian power-law fluid is investigated for power-law indices of 0.75, 1 and 1.4. The results are compared with the ones in which the magnetic field is not applied. It is found that the implementation of a magnetic field for different fluid indices in different Rayleigh numbers does not show similar behaviors and the results show that the magnetic field affects the convection flow, leading to a reduction in it. Also can be said that with the implementation of a magnetic field in the range of indices &lt;em&gt;n&lt;/em&gt; ≥ 1 for power-law model fluid, increased Rayleigh number leads to reduced average Nusselt number and for &lt;em&gt;n&lt;/em&gt; ˂ 1, the average Nusselt increases. For &lt;em&gt;n&lt;/em&gt; ˂ 1, with increased Rayleigh number in the presence of a fixed magnetic field, free convection can be weakened while this trend for &lt;em&gt;n&lt;/em&gt; ˂ 1 occurs with reduced Rayleigh number.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Non- Newtonian fluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Power-law model</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">magnetic field</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Natural convection</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3513_0ffaca95e3e5242ba1097ad8a9a6e95d.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental Investigation on the Thermal Resistance of Straight Heat Pipes with Double-Ended Cooling and Middle-Heating at Different Tilt Angles</ArticleTitle>
<VernacularTitle>Experimental Investigation on the Thermal Resistance of Straight Heat Pipes with Double-Ended Cooling and Middle-Heating at Different Tilt Angles</VernacularTitle>
			<FirstPage>279</FirstPage>
			<LastPage>302</LastPage>
			<ELocationID EIdType="pii">3490</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.15733.6194</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Behnam</FirstName>
					<LastName>Habibnezhad Ledari</LastName>
<Affiliation>Department of Mechanical Engineering, University of Kashan, Kashan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Sabzpooshani</LastName>
<Affiliation>Department of Mechanical Engineering, University of Kashan, Kashan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>02</Month>
					<Day>01</Day>
				</PubDate>
			</History>
		<Abstract>An experimental study has been investigated on the thermal resistance of straight heat pipes with double-ended cooling and middle heating at different tilt angles. Two cooling blocks installed on both ends of heat pipes and a coil heater placed in the middle as the condenser and evaporator sections respectively. The experiments were conducted at inclinations 0° to 90° for heat inputs 20 to 80 W. The effects of heat input variation, cooling water flow rate and tilt angle on the thermal resistance of heat pipes were studied. The obtained results compared with the conventional heat pipes. The results showed that by using the new cooling approach, the thermal resistance of the heat pipes can be reduced significantly. Also, in low heat inputs, increasing the cooling water flow rate increases the thermal performance of the heat pipes. The experimental results indicated that the tilt angle has a significant effect on the thermal resistance of the heat pipes. The minimum thermal resistance and the maximum effective thermal conductivity coefficient values are 0.2533 °C/W and 14072.65 W/m°C respectively, and they were observed at the tilt angle equal to 60° and for heat input of 60 W.</Abstract>
			<OtherAbstract Language="FA">An experimental study has been investigated on the thermal resistance of straight heat pipes with double-ended cooling and middle heating at different tilt angles. Two cooling blocks installed on both ends of heat pipes and a coil heater placed in the middle as the condenser and evaporator sections respectively. The experiments were conducted at inclinations 0° to 90° for heat inputs 20 to 80 W. The effects of heat input variation, cooling water flow rate and tilt angle on the thermal resistance of heat pipes were studied. The obtained results compared with the conventional heat pipes. The results showed that by using the new cooling approach, the thermal resistance of the heat pipes can be reduced significantly. Also, in low heat inputs, increasing the cooling water flow rate increases the thermal performance of the heat pipes. The experimental results indicated that the tilt angle has a significant effect on the thermal resistance of the heat pipes. The minimum thermal resistance and the maximum effective thermal conductivity coefficient values are 0.2533 °C/W and 14072.65 W/m°C respectively, and they were observed at the tilt angle equal to 60° and for heat input of 60 W.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Straight Heat pipe</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal resistance</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Double-ended cooling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Middle heating</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Experimental Method</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3490_72f67e70f6b7cdc4cc893edaddf0c4c6.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>53</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Real Time Solution for Inverse Heat Conduction Problem in One-Dimensional Plate Utilizing Fuzzy- Proportional–Integral–Derivative Controller</ArticleTitle>
<VernacularTitle>Real Time Solution for Inverse Heat Conduction Problem in One-Dimensional Plate Utilizing Fuzzy- Proportional–Integral–Derivative Controller</VernacularTitle>
			<FirstPage>303</FirstPage>
			<LastPage>316</LastPage>
			<ELocationID EIdType="pii">3574</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2019.16092.6269</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Amir Hossein</FirstName>
					<LastName>Rabiee</LastName>
<Affiliation>mechanical engineering, arak university of technology</Affiliation>

</Author>
<Author>
					<FirstName>Somayeh</FirstName>
					<LastName>Farahani</LastName>
<Affiliation>صنعتی اراک-مهندسی مکانیک</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>04</Month>
					<Day>09</Day>
				</PubDate>
			</History>
		<Abstract>This paper dealing with a novel algorithm based on features of fuzzy- proportional–integral–derivative controllers to estimate heat flux on the inverse heat conduction problems. The main structure of Fuzzy- proportional–integral–derivative is a proportional–integral–derivative controller in which the proportional, integrator and the derivative gains are obtained online by fuzzy system. The input of the algorithm is the measured temperatures within the model. In each time-step, the smart controller calculates the proper heat flux in order to adjust the measured temperature with the desired input temperature. The model studied a flat plate with an insulated surface and an active level that affects the variable heat flux at the time. The variation of heat flux with time can be considered to be constant, step, and triangular. The measured temperatures are obtained at the active and inactive surface with numerical simulation. The effect of noise level at the measurement temperatures on the accuracy of the proposed method is investigated. The estimations and error analysis indicate that this algorithm is very successful in estimating the different forms of heat flux with different amounts of noise and the different thermocouple positions in the wall. The accuracy of the proposed sequence method is higher than that of the Tikhonov method.</Abstract>
			<OtherAbstract Language="FA">This paper dealing with a novel algorithm based on features of fuzzy- proportional–integral–derivative controllers to estimate heat flux on the inverse heat conduction problems. The main structure of Fuzzy- proportional–integral–derivative is a proportional–integral–derivative controller in which the proportional, integrator and the derivative gains are obtained online by fuzzy system. The input of the algorithm is the measured temperatures within the model. In each time-step, the smart controller calculates the proper heat flux in order to adjust the measured temperature with the desired input temperature. The model studied a flat plate with an insulated surface and an active level that affects the variable heat flux at the time. The variation of heat flux with time can be considered to be constant, step, and triangular. The measured temperatures are obtained at the active and inactive surface with numerical simulation. The effect of noise level at the measurement temperatures on the accuracy of the proposed method is investigated. The estimations and error analysis indicate that this algorithm is very successful in estimating the different forms of heat flux with different amounts of noise and the different thermocouple positions in the wall. The accuracy of the proposed sequence method is higher than that of the Tikhonov method.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Heat Flux</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sequential method</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Inverse problem</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Filter</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fuzzy- proportional–integral–derivative controller</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_3574_1b9f38268c50805669fd8caf8f3cc84a.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
