<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>56</Volume>
				<Issue>10</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Ensemble Learning based Model for Multi-Sensor Vibration Data Fusion in Gearbox Diagnosis</ArticleTitle>
<VernacularTitle>Ensemble Learning based Model for Multi-Sensor Vibration Data Fusion in Gearbox Diagnosis</VernacularTitle>
			<FirstPage>1329</FirstPage>
			<LastPage>1354</LastPage>
			<ELocationID EIdType="pii">5684</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2025.23606.7787</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Hesam Addin</FirstName>
					<LastName>Arghand</LastName>
<Affiliation>Department of Mechanical Engineering, University of Zanjan, Zanjan, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-3191-3510</Identifier>

</Author>
<Author>
					<FirstName>Amir Hossein</FirstName>
					<LastName>Kheybarinejhad</LastName>
<Affiliation>Master of Mechanical Engineering, Department of Mechanical Engineering, University of Zanjan, Zanjan, Iran</Affiliation>
<Identifier Source="ORCID">0009-0003-6936-8209</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>10</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		    <Abstract>This study investigates recorded vibration signals from a laboratory gearbox to assess health condition and identify fault types, using a proposed ensemble-based machine learning algorithm. A single-stage gearbox was designed and tested in laboratory under four healththe  states: no faults, tooth root crack, tooth breakage, and pitting on the tooth, across varying loads and speeds. Vibration was recorded at six points. Totally 792 signals (6 signals from 132 tests) were collected. For the data from each sensor, a support vector machine (SVM) classifier with a linear kernel was trained. Next, fault detection accuracy was assessed and compared for each transducer individually. A new data fusion algorithm, inspired by random forest (RF), was developed to combine data from the six sensors. The results showed that the proposed ensemble algorithm provides higher detection accuracy rather than the individual classifiers for each sensor. In addition, a novel method is introduced to estimate the confidence level (CL) of the classification by the proposed algorithm. In addition, it is demonstrated that the proposed algorithm can effectively diagnose faults with incomplete data (regardless of how many sensors are used from the total of six). As expected, using data from fewer sensors resulted in reduced accuracy and CL.</Abstract>
			<OtherAbstract Language="FA">This study investigates recorded vibration signals from a laboratory gearbox to assess health condition and identify fault types, using a proposed ensemble-based machine learning algorithm. A single-stage gearbox was designed and tested in laboratory under four healththe  states: no faults, tooth root crack, tooth breakage, and pitting on the tooth, across varying loads and speeds. Vibration was recorded at six points. Totally 792 signals (6 signals from 132 tests) were collected. For the data from each sensor, a support vector machine (SVM) classifier with a linear kernel was trained. Next, fault detection accuracy was assessed and compared for each transducer individually. A new data fusion algorithm, inspired by random forest (RF), was developed to combine data from the six sensors. The results showed that the proposed ensemble algorithm provides higher detection accuracy rather than the individual classifiers for each sensor. In addition, a novel method is introduced to estimate the confidence level (CL) of the classification by the proposed algorithm. In addition, it is demonstrated that the proposed algorithm can effectively diagnose faults with incomplete data (regardless of how many sensors are used from the total of six). As expected, using data from fewer sensors resulted in reduced accuracy and CL.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Vibration Condition Monitoring</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Gearbox Diagnosis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Ensemble Machine Learning</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Confidence Level</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sensor Fusion</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_5684_1959eb9d5a0f7ebc58ebde81d5df400d.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>56</Volume>
				<Issue>10</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Heat Transfer Analysis of a Catalytic Monopropellant Thruster Under the Influence of Wall Thickness</ArticleTitle>
<VernacularTitle>Heat Transfer Analysis of a Catalytic Monopropellant Thruster Under the Influence of Wall Thickness</VernacularTitle>
			<FirstPage>1355</FirstPage>
			<LastPage>1376</LastPage>
			<ELocationID EIdType="pii">5685</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2025.23659.7795</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mohammad Reza</FirstName>
					<LastName>Salimi</LastName>
<Affiliation>Space Science R.G., Astronautic Department, Aerospace Research Institute. Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Hadiseh</FirstName>
					<LastName>Karimaei</LastName>
<Affiliation>Ari</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>11</Month>
					<Day>09</Day>
				</PubDate>
			</History>
		    <Abstract>Thermal control of a space system is essential for optimal performance and mission success. In this paper, the decomposition chamber of a catalytic monopropellant thruster has been numerically simulated at the pore scale. The effect of this wall thickness, 1-5 mm, on radiation heat transfer and conduction has been investigated. The importance of the maximum temperature in the structural considerations of the thruster, on the one hand, and the increase in the weight of the thruster due to the increase in the thickness of the wall to reduce the maximum temperature on the other hand, make the simultaneous evaluation of these parameters inevitable. The results showed that as the thickness of the wall increases, a significant drop up to about three times in the radiation heat flux has occurred. The dominant type of heat transfer in the current problem is conduction. The heat soak back upstream is up to 1000 times greater than the intensity of radiative heat transfer. Increasing the thickness of the wall causes an increase in the heat soak back on the thermal control system. The novelty is to investigate the geometric shape and wall thickness of a catalytic monopropellant thruster on the rate of radiation and conduction heat transfer to the upstream parts.</Abstract>
			<OtherAbstract Language="FA">Thermal control of a space system is essential for optimal performance and mission success. In this paper, the decomposition chamber of a catalytic monopropellant thruster has been numerically simulated at the pore scale. The effect of this wall thickness, 1-5 mm, on radiation heat transfer and conduction has been investigated. The importance of the maximum temperature in the structural considerations of the thruster, on the one hand, and the increase in the weight of the thruster due to the increase in the thickness of the wall to reduce the maximum temperature on the other hand, make the simultaneous evaluation of these parameters inevitable. The results showed that as the thickness of the wall increases, a significant drop up to about three times in the radiation heat flux has occurred. The dominant type of heat transfer in the current problem is conduction. The heat soak back upstream is up to 1000 times greater than the intensity of radiative heat transfer. Increasing the thickness of the wall causes an increase in the heat soak back on the thermal control system. The novelty is to investigate the geometric shape and wall thickness of a catalytic monopropellant thruster on the rate of radiation and conduction heat transfer to the upstream parts.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Monopropellant thruster</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Catalyst bed</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Conduction</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Radiation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal control system (TCS)</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_5685_a1b07b8980c5acf5ef69cff16ebb1f42.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>56</Volume>
				<Issue>10</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Modeling and Thermodynamic Analysis of Vacuum Crystallizer with Heat Pump</ArticleTitle>
<VernacularTitle>Modeling and Thermodynamic Analysis of Vacuum Crystallizer with Heat Pump</VernacularTitle>
			<FirstPage>1377</FirstPage>
			<LastPage>1398</LastPage>
			<ELocationID EIdType="pii">5687</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2025.23430.7770</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Amir</FirstName>
					<LastName>Mehrdar</LastName>
<Affiliation>Department of Mechanical Engineering, Shahrood Univ of Tech, Shahrood, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohsen</FirstName>
					<LastName>Nazari</LastName>
<Affiliation>Department of Mechanical Engineering, Shahrood Univ of Tech, Shahrood, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mostafa</FirstName>
					<LastName>Nazari</LastName>
<Affiliation>Department of Mechanical Engineering, Shahrood Univ of Tech, Shahrood, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Maryam</FirstName>
					<LastName>Ramezani Bazan</LastName>
<Affiliation>Department of Mechanical Engineering, Shahrood Univ of Tech, Shahrood, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>08</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		    <Abstract>In this article, a forced circulation crystallizer under a vacuum, which consists of crystallizer, pump, and heat exchanger, is proposed for the purpose of providing fresh water for consumption. To simultaneously supply the heating load of the crystallizer and also to distill the water vapor coming out of the crystallizer, a heat pump has been used as a new method. A laboratory set is designed and built to demonstrate the feasibility of the proposed system, which includes a forced circulation crystallizer cycle. The average error percentage between the laboratory and simulation results was reported as 4.8%. The results indicate that by changing the inlet temperature and pressure of the crystallizer, the rate of salt crystal production and freshwater production increases by 0.65 and 19.81 kg/h, respectively. Electric energy consumption also decreases with the increase of feed water inlet temperature and the heat capacity of the heat exchanger, and the lowest amount of electric energy consumption occurs at the temperature of 50 degrees Celsius, the pressure of the crystallizer is 0.085 bar, and the heat capacity of the heat exchanger is 13.25 kw.</Abstract>
			<OtherAbstract Language="FA">In this article, a forced circulation crystallizer under a vacuum, which consists of crystallizer, pump, and heat exchanger, is proposed for the purpose of providing fresh water for consumption. To simultaneously supply the heating load of the crystallizer and also to distill the water vapor coming out of the crystallizer, a heat pump has been used as a new method. A laboratory set is designed and built to demonstrate the feasibility of the proposed system, which includes a forced circulation crystallizer cycle. The average error percentage between the laboratory and simulation results was reported as 4.8%. The results indicate that by changing the inlet temperature and pressure of the crystallizer, the rate of salt crystal production and freshwater production increases by 0.65 and 19.81 kg/h, respectively. Electric energy consumption also decreases with the increase of feed water inlet temperature and the heat capacity of the heat exchanger, and the lowest amount of electric energy consumption occurs at the temperature of 50 degrees Celsius, the pressure of the crystallizer is 0.085 bar, and the heat capacity of the heat exchanger is 13.25 kw.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Forced circulation crystallizer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heat pump</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">desalination</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ZLD</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">numerical simulation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_5687_218ac3fe3df6ff2c8fe8f9353f1084f6.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>56</Volume>
				<Issue>10</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical investigation of thermal comfort conditions for a human in a room equipped with a ceiling radiant cooling system</ArticleTitle>
<VernacularTitle>Numerical investigation of thermal comfort conditions for a human in a room equipped with a ceiling radiant cooling system</VernacularTitle>
			<FirstPage>1399</FirstPage>
			<LastPage>1428</LastPage>
			<ELocationID EIdType="pii">5688</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2025.23738.7808</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mohammad</FirstName>
					<LastName>Alipour Dehsari</LastName>
<Affiliation>University of Guilan, Rasht, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Amin</FirstName>
					<LastName>Haghighi Poshtiri</LastName>
<Affiliation>Faculty of Mechanical Engineering
University of Guilan</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>09</Day>
				</PubDate>
			</History>
		    <Abstract>In this study, the cooling conditions and thermal comfort in a room occupied by humans and equipped with a radiant ceiling cooling system were numerically investigated. The simulations were conducted for the hottest day of the average 10-year period in Tehran and in four geographical orientations. Low-Reynolds k-ε models, discrete ordinates, and ray tracing were used to analyze airflow, radiation, and solar radiation, and thermal comfort conditions were evaluated using the Fanger model. The results showed that in the room with a western external wall, the maximum cooling load occurs at 14:00, and the ceiling temperature should be set at approximately 12°C. However, when using clear glass, this temperature must be reduced to 7°C, requiring 27% more cooling load. Coated glass improved the PMV index and reduced dissatisfaction; in the western wall, PMV decreased from 0.5 to 0.32, and dissatisfaction decreased from 10.2% to 7.1%. Dissatisfaction due to vertical temperature differences was less than 3%, but for warm floors in eastern and western walls with clear glass, it reached 25.1% and 25.5%, respectively. Dissatisfaction due to the draft rate was less than 10% in all cases.</Abstract>
			<OtherAbstract Language="FA">In this study, the cooling conditions and thermal comfort in a room occupied by humans and equipped with a radiant ceiling cooling system were numerically investigated. The simulations were conducted for the hottest day of the average 10-year period in Tehran and in four geographical orientations. Low-Reynolds k-ε models, discrete ordinates, and ray tracing were used to analyze airflow, radiation, and solar radiation, and thermal comfort conditions were evaluated using the Fanger model. The results showed that in the room with a western external wall, the maximum cooling load occurs at 14:00, and the ceiling temperature should be set at approximately 12°C. However, when using clear glass, this temperature must be reduced to 7°C, requiring 27% more cooling load. Coated glass improved the PMV index and reduced dissatisfaction; in the western wall, PMV decreased from 0.5 to 0.32, and dissatisfaction decreased from 10.2% to 7.1%. Dissatisfaction due to vertical temperature differences was less than 3%, but for warm floors in eastern and western walls with clear glass, it reached 25.1% and 25.5%, respectively. Dissatisfaction due to the draft rate was less than 10% in all cases.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Radiant Cooling Ceiling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Solar radiation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal comfort</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Human Presence</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_5688_1f029c1e1abaaf0605807b7f91552d36.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>56</Volume>
				<Issue>10</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Comprehensive Dynamic Modeling and Characterization of a Piezoelectric Droplet Dispenser</ArticleTitle>
<VernacularTitle>Comprehensive Dynamic Modeling and Characterization of a Piezoelectric Droplet Dispenser</VernacularTitle>
			<FirstPage>1429</FirstPage>
			<LastPage>1450</LastPage>
			<ELocationID EIdType="pii">5689</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2025.23611.7788</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Pouya</FirstName>
					<LastName>Firuzy Rad</LastName>
<Affiliation>Department of mechanical engineering, Amirkabir university of technology</Affiliation>

</Author>
<Author>
					<FirstName>Hamed</FirstName>
					<LastName>Ghafarirad</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>S.mehdi</FirstName>
					<LastName>Rezaei</LastName>
<Affiliation>Amirkabir University of Technology</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>10</Month>
					<Day>19</Day>
				</PubDate>
			</History>
		    <Abstract>Piezoelectric dispensers are widely applicable devices across many industries. However, their electromechanical structure often poses complexity in dynamic modeling. The interplay of many components especially compliant mechanisms and piezoelectric actuators makes modeling of the system challenging. In this study, the components of the system have been modeled individually and coupled together to predict the system behavior. For analyzing the bridge-type compliant mechanism, an appropriate method is proposed to model the structure with limited states. The mentioned method can predict the component behavior without sacrificing the precision which makes it ideal for coupling with other components dynamics. Additionally, a non-linear modeling approach is introduced to capture the piezoelectric non-linear hysteresis behavior. Finally, by coupling the whole system dynamic,  a comprehensive model is reached. The model developed for the compliant mechanism is individually validated by FEM software and experiments to prove the accuracy. The hysteresis nonlinear model is also identified and validated with the experiments with R squared exceeding 0.98. The entire coupled dynamics of the electromechanical system are identified and tested across several input frequencies. R-squared values exceed 0.95 for all input frequencies, affirming the accuracy of the dynamic model.</Abstract>
			<OtherAbstract Language="FA">Piezoelectric dispensers are widely applicable devices across many industries. However, their electromechanical structure often poses complexity in dynamic modeling. The interplay of many components especially compliant mechanisms and piezoelectric actuators makes modeling of the system challenging. In this study, the components of the system have been modeled individually and coupled together to predict the system behavior. For analyzing the bridge-type compliant mechanism, an appropriate method is proposed to model the structure with limited states. The mentioned method can predict the component behavior without sacrificing the precision which makes it ideal for coupling with other components dynamics. Additionally, a non-linear modeling approach is introduced to capture the piezoelectric non-linear hysteresis behavior. Finally, by coupling the whole system dynamic,  a comprehensive model is reached. The model developed for the compliant mechanism is individually validated by FEM software and experiments to prove the accuracy. The hysteresis nonlinear model is also identified and validated with the experiments with R squared exceeding 0.98. The entire coupled dynamics of the electromechanical system are identified and tested across several input frequencies. R-squared values exceed 0.95 for all input frequencies, affirming the accuracy of the dynamic model.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Droplet dispensing system</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Piezoelectric</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Dynamic modeling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Compliant mechanism</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hysteresis</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_5689_8ba6c657b03fc7c8dd4dff8e45defcd2.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Mechanical Engineering</JournalTitle>
				<Issn>2008-6032</Issn>
				<Volume>56</Volume>
				<Issue>10</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Investigation of the performance of multi-cellular energy absorbers with functionally graded thickness under impact loading</ArticleTitle>
<VernacularTitle>Investigation of the performance of multi-cellular energy absorbers with functionally graded thickness under impact loading</VernacularTitle>
			<FirstPage>1451</FirstPage>
			<LastPage>1472</LastPage>
			<ELocationID EIdType="pii">5691</ELocationID>
			
<ELocationID EIdType="doi">10.22060/mej.2025.23763.7810</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Saeid</FirstName>
					<LastName>Feli</LastName>
<Affiliation>فنی مهندسی، دانشگاه رازی، کرمانشاه، ایران</Affiliation>
<Identifier Source="ORCID">0000-0003-0638-2380</Identifier>

</Author>
<Author>
					<FirstName>Mohamad Hossein</FirstName>
					<LastName>Kiani</LastName>
<Affiliation>razi university</Affiliation>

</Author>
<Author>
					<FirstName>Seyed Sajad</FirstName>
					<LastName>Jafari</LastName>
<Affiliation>Assistant Professor, Department of Mechanical Engineering, Hamedan University of Technology, Hamedan, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0002-9155-592X</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>20</Day>
				</PubDate>
			</History>
		    <Abstract>In recent years, multi-cellular structures have gained significant attention as energy absorbers in automotive engineering to mitigate occupant injuries in collisions. This paper investigates the energy absorption of square shape thin-walled structures with constant thickness and functionally graded thickness under dynamic axial impact loading using both analytical and numerical methods. Four types of square profiles, including single-cell, two-cell, four-cell, and five-cell profiles, were studied. Simulations were conducted using the Finite Element Analysis Abaqus software to obtain force-displacement and energy-time curves. In the analytical method, equations for absorbed energy and axial collapse force were derived based on the folding theory and extended to profiles with functionally graded thickness. There is good agreement between analytical and numerical methods. Results of the analytical and numerical methods showed that five-cell profiles performed significantly better than single-cell profiles. In numerical simulations and analytical solutions, five-cell profiles absorbed 66% and 56% more energy, respectively, compared to single-cell profiles in both constant and functionally graded thickness conditions. The average collapse force in the analytical method was compared with numerical results, and the computational error was less than 9%.</Abstract>
			<OtherAbstract Language="FA">In recent years, multi-cellular structures have gained significant attention as energy absorbers in automotive engineering to mitigate occupant injuries in collisions. This paper investigates the energy absorption of square shape thin-walled structures with constant thickness and functionally graded thickness under dynamic axial impact loading using both analytical and numerical methods. Four types of square profiles, including single-cell, two-cell, four-cell, and five-cell profiles, were studied. Simulations were conducted using the Finite Element Analysis Abaqus software to obtain force-displacement and energy-time curves. In the analytical method, equations for absorbed energy and axial collapse force were derived based on the folding theory and extended to profiles with functionally graded thickness. There is good agreement between analytical and numerical methods. Results of the analytical and numerical methods showed that five-cell profiles performed significantly better than single-cell profiles. In numerical simulations and analytical solutions, five-cell profiles absorbed 66% and 56% more energy, respectively, compared to single-cell profiles in both constant and functionally graded thickness conditions. The average collapse force in the analytical method was compared with numerical results, and the computational error was less than 9%.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">thin-wall structure</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">functionally graded thickness</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Energy Absorption</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Analytical and Numerical methods</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Impact loading</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mej.aut.ac.ir/article_5691_87784eca6b0dea1dff92478fb786b401.pdf</ArchiveCopySource>
</Article>
</ArticleSet>