Investigation of Thermo-Hydraulic Parameters of Reactor Containment due to Cold-Leg Break Accident

Document Type : Research Article

Authors

1 Associate Professor, Department of Mechanical Engineering, Azarbaijan Shahid Madani University, Tabriz, Iran.

2 Department of Mechanical Engineering, Urmia University of Technology, Urmia, Iran.

3 Ph.D. Candidate, Department of Mechanical Engineering, Urmia University of Technology, Urmia, Iran.

Abstract

Since the nuclear energy has been recognized as a useful energy, the subject of structure, operation and safety and environmental protection have also been important. In the nuclear reactors, one of the most dangerous accidents that can occur is the loss of coolant accident, that the most important of these events is the guillotine breaking in cold or hot leg coolant, which, this will melt the reactor core if it is not stopped. This paper presents one of the most dangerous accidents in reactor containments known as loss of coolant accident in its worst condition which is called large break loss of coolant accident. The specific type of large break loss of coolant accident is double ended cold leg break which means totally guillotine type of break in cold leg pipe. This modeling is performed in single volume method in Advanced Pressurized water reactor which is one of the most sophisticated safe reactors that has ever been built. The conservation mass and energy equations have been used in this modeling and the modeling software applied in our analysis is MATLAB, and the results are compared with the Advanced Pressurized-1000 water reactor safety, security and environmental reports.

Keywords

Main Subjects


[1] UK Compliance document for AP1000 design, Section A UK safety case Overview, A.2 AP1000 safety philosophy, A 50, (2007).
[2] The Westinghouse AP1000 Advanced Nuclear Plant, Plant Description,Copyright 2003, Westinghouse Electric Co., LLC.,(2007) 17.
[3] UK AP1000 Safety, Security, and Environmental Report,Chapter6, 6.2.2.2.3 Component Description, (2007) 2-18.

[4] Heng Xie, Numerical simulation of AP1000 LBLOCA with SCDAP/RELAP 4.0 cod, Journal of Nuclear Science and Technology, 54)2017( 969-976.

[5] Eltayeb Yousif, Zhijian Zhang, Zhaofei Tian, and Hao-ran Ju, Simulation and Analysis of Small Break LOCA for AP1000 Using RELAP5-MV and Its Comparison with NOTRUMP Code, Science and Technology of Nuclear Installations, 45(2017) 13.

[6] Sh. Sheykhi, S. Talebi, M. Soroush, E. Masoumi, Thermal-hydraulic and stress analysis of AP1000 reactor containment during LOCA in dry cooling mode, Nuclear Science and Techniques,73(2017) 13.

[7] J. Yang, W. W. Wang, S. Z. Qiu, W. X. Tian, G. H. Su, and Y. W. Wu,  Simulation and analysis on 10-in. cold leg small break LOCA for AP1000,Annals of Nuclear Energy, 46(2012) 81–89.

[8] L. L. Zheng Limin, Analysis of reactor coolant system leak for AP1000 nuclear power plant, Nuclear Techniques, 39(2016) 9.

[9] Omid Noori-Kalkhoran, Amir Saied Shirani, Rohollah Ahangari, Simulation Of Containment Pressurization In ALarge Break-Loss Of Coolant Accident Using Single-Cell and Multicell Models and CONTAIN Code, Nuclear Engineering and Technology, 48(2016) 1140-1153.
 
[10] Neil E. Todreas, Mujid S. Kazimi, NUCLEAR SYSTEMS 1 Thermal Hydraulic Fundamentals, Massachusetts Institute of Technology,HEMISPHERE PUBLISHING CORPORATION 1990, Chapter 7, (2007) 239.
[11] F.P. Incropera, D.P. DeWitt, Fundamentals of Heat Transfer, Wiley, Hoboken, NJ, (1981).
[12] Omid Noori-Kalkhoran, Mohammad Rahgoshay, Abdolhamid Minuchehr, Amir Saied Shirani, Analysis of thermal–hydraulic parameters of WWER-1000containment in a large break LOCA, Annals of Nuclear Energy, 68(2014) 101-111.
[13] UK AP1000 Safety, Security, and Environmental Report, Chapter3,8-122, (2007) 3.
[14] UK AP1000 Safety, Security and Environmental Report, Chapter 6, Section LOCA, DECL, (2007).
[15] Matlab-2016a. Mathworks Company, March (2016).